Canada Gazette, Part I, Volume 156, Number 25: Canada-Nova Scotia Offshore Area Petroleum Operations Framework Regulations

June 18, 2022

Statutory authority
Canada-Nova Scotia Offshore Petroleum Resources Accord Implementation Act

Sponsoring departments
Department of Natural Resources Department of the Environment

REGULATORY IMPACT ANALYSIS STATEMENT

For the Regulatory Impact Analysis Statement, see the Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations.

PROPOSED REGULATORY TEXT

Notice is given, pursuant to subsection 154(1) of the Canada-Nova Scotia Offshore Petroleum Resources Accord Implementation Actfootnote a, that the Governor in Council, pursuant to subsections 153(1)footnote b and (3)footnote c of that Act, proposes to make the annexed Canada-Nova Scotia Offshore Area Petroleum Operations Framework Regulations.

Interested persons may make representations concerning the proposed Regulations within 30 days after the date of publication of this notice. All such representations must cite the Canada Gazette, Part I, and the date of publication of this notice, and be addressed to Cheryl McNeil, Senior Policy Advisor, Offshore Petroleum Management Division, Fuels Sector, Department of Natural Resources (email: cheryl.mcneil@nrcan-rncan.gc.ca).

Ottawa, June 9, 2022

Wendy Nixon
Assistant Clerk of the Privy Council

TABLE OF PROVISIONS

Canada-Nova Scotia Offshore Area Petroleum Operations Framework Regulations

Interpretation

1 Definitions

2 Incorporation by reference

Experience, Training, Qualifications and Competence

3 Requirements

PART 1

Management System

4 Development

5 Requirements

6 Human resources

7 Implementation

8 Continual improvement

PART 2

Authorization

Application

9 Documents and information

10 Safety plan

11 Environmental protection plan

12 Contingency plan

13 Spill-treating agent — section 142.21 of Act

14 Field data acquisition program

15 Flow system, calculation and allocation

16 Decommissioning and abandonment plan

Well Approvals

17 Well operation

18 Well data acquisition program

19 Well verification scheme

20 Suspension of well approval

21 Revocation of well approval

22 Suspension or abandonment of well

Development Plan

23 Well approval — subsection 143(1) of Act

24 Concept safety analysis

25 Resource management plan — paragraph 143(3)(b) of Act

PART 3

Certificate of Fitness

Application

26 Prescribed installations — section 143.2 of Act

Requirements for Certification

27 Issuance of certificate — requirements and conditions

28 Conflict of interest — subsection 143.2(4) of Act

29 Certification plan

30 Scope of work

31 Certification period — five years

32 Applicable site or region

33 Renewal of certificate

34 Revalidation — scope of work

35 Invalidity

Change of Certifying Authority

36 Before initial certificate

Administrative Requirements

37 Organizational structure

38 Annual report

PART 4

General Requirements for Authorized Works and Activities

General

39 Safety and protection of environment

40 Physical and environmental conditions

41 Location of infrastructure or equipment

42 Accessibility, storage and handling of consumables

43 Storage and handling of chemical substances

44 Tampering with equipment

45 Cessation of work or activity

Document Availability

46 Copy of authorization and other documents

47 Emergency response procedures and other documentation

Plans

48 Implementation

PART 5

Geoscientific Programs, Geotechnical Programs and Environmental Programs

Equipment, Materials and Property

49 Measures

50 Certification

51 Damage to property

Energy Sources

52 General requirements

53 Testing of energy sources

Primary Vessel

54 Classification

Destruction, Discard or Removal

55 Destroy, discard or remove from Canada

PART 6

Drilling and Production

General

56 Definition of termination

57 Spacing and production rates

58 Name, classification or status of well

59 Pool, zone or field

Evaluation of Wells, Pools and Fields

60 Implementation of data acquisition programs

61 Formation testing and sampling

62 Formation flow test

63 Samples and cores

64 Remaining conventional core

65 Notice before disposal

Location of Wells

66 Reference for well depth

67 Directional and deviation surveys

Well Integrity

68 Well control

69 Casing and cementing

70 Formation leak-off or integrity test

71 Completion, testing and operation

72 Production tubing

73 Safe operations and production

Measurements

74 Flow, volume and quantity

75 Allocation of group production

76 Testing and maintenance

77 Calibration

78 Proration tests

Production Conservation

79 Resource management

80 Commingled production

81 Pilot scheme

82 Prohibition against flaring or venting

83 Venting limit

84 Prohibition against oil burning

Spill-treating Agent

85 Small-scale test — paragraph 166.1(1)(b) of Act

86 Factors — subsection 166.1(3) of Act

87 Variation of approval

Well Termination

88 Conditions for suspension or abandonment

89 Additional condition for suspension

90 Additional condition for abandonment

91 Conditions for drilling installation removal

PART 7

Diving Projects

92 Definition of light dive craft

93 Vessel used in diving project

94 Dynamic positioning system

95 Light dive craft

PART 8

Installations, Wells, Pipelines and Vessels

Installations

General

96 Definitions

97 Safety and environmental protection

98 Design of installation — certification plan

Quality Assurance

99 Quality assurance program

Work Permits

100 Requirements

101 Operator obligations

Design Analysis and Risk Assessment

102 Innovations

103 Physical and environmental conditions

104 Design for intended use and location

105 Conditions for safe operation and survival

106 Risk assessment — fire, explosion and hazardous gas

107 Reliability and availability

Installations — Design, Transportation, Arrangement and Other Requirements

108 Monitoring program for environment

109 Maintenance

110 Materials for installations

111 Passive fire and blast protection

112 Hazardous and non-hazardous areas

113 Ventilation of enclosed hazardous areas

114 Ignition prevention

115 Safe means of escape, evacuation and rescue

116 Exits, access and escape routes

117 Life-saving appliances for installation

118 Design for removal of installation

119 Transportation and positioning

Systems and Equipment — Design, Installation, Commission and Other Requirements

120 Electrical system

121 Control systems — certification plan

122 Integrated software-dependent control systems

123 Emergency electrical power supply

124 Navigation lights and sound-signalling appliances

125 Communication system

126 General alarm system

127 Gas release system

128 Fire and gas detection system

129 Emergency shutdown system

130 Fire protection systems and equipment

131 Boilers and pressure systems — certification plan

132 Mechanical equipment — certification plan

133 Materials handling equipment

134 Subsea production system — certification plan

135 Temporary or portable equipment

Platforms — Additional Requirements

136 Classification

137 Air gap

138 Stability

139 Assessment — self-elevating mobile offshore platform

140 Ballast and bilge systems

141 Watertight and weathertight integrity and freeboard — Codes

142 Station-keeping

143 Mooring system design

144 Disconnectable mooring system

145 Dynamic positioning system design

146 Disconnect system

147 Decisions and exemptions

Asset Integrity

148 Requirements

149 Non-destructive examination

150 Winterization

151 Corrosion management

Operation and Maintenance

152 Limits and requirements

153 Operations manual

154 Programs

155 Maintenance program

156 Preservation program

157 Weight control program

158 Notice of repair, replacement and modification

Wells

159 Drilling fluid systems

160 Drilling riser

161 Fail-safe subsurface safety valve

162 Well tubulars, trees and wellheads

163 Formation flow test equipment

Pipelines

164 Pipeline integrity — standard

Monitoring of Installations, Wells and Pipelines

165 Monitoring of systems

166 Notice of deterioration — Chief Safety Officer

PART 9

Support Operations

167 Support craft

168 Support craft — availability and equipment

169 Rescue boat

170 Safety zone — installation

171 Landing area

172 Aircraft service provider

173 Classification

PART 10

Notice, Records, Reports and Other Information for Authorized Works and Activities

General

174 Definition of shotpoint

175 Reportable incidents

176 Accessibility of records

177 Critical information

178 Safety report

179 Annual reports

Geoscientific, Geotechnical and Environmental Programs

180 Notice — key dates

181 Weekly status reports

182 Environmental report — programs

183 Final reports

184 Final interpretation report not required

185 Data purchases

Drilling and Production

186 Reference

187 Results, data, analysis and schematics

188 Survey

189 Survey plan

190 Critical information

191 Daily production record

192 Formation flow test report

193 Pilot scheme report

194 Daily reports

195 Monthly production report

196 Well reports and other information

197 Environmental report — drilling

198 Annual environmental report — production and pipeline

199 Annual production report

200 Gas venting records

201 Compressor records

202 Fugitive emission records

203 Record retention period

Diving Projects or Construction Activities

204 Weekly status reports

PART 11

Repeals and Coming into Force

205 Repeals

Coming into Force

206 Six months after publication

SCHEDULE 1

PART 1

Provisions of these Regulations

PART 2

Provisions of the Canada-Nova Scotia Offshore Area Occupational Health and Safety Regulations

SCHEDULE 2

Canada-Nova Scotia Offshore Area Petroleum Operations Framework Regulations

Interpretation

Definitions

1 (1) The following definitions apply in these Regulations.

accidental event
means an unexpected or unplanned event or circumstance or series of unexpected or unplanned events or circumstances that may lead to the loss of one life or damage to the environment, including pollution. (événement accidentel)
accommodations area
means the area of an installation or vessel that contains the sleeping quarters, dining areas, food preparation areas, general recreation areas, office areas and medical rooms, and includes all washrooms in that area. (aire d’habitation)
accommodations installation
means an installation that is used to accommodate persons at a production site, drill site or dive site and that functions independently of a production installation, drilling installation or diving installation. (installation d’habitation)
Act
means the Canada-Nova Scotia Offshore Petroleum Resources Accord Implementation Act. (Loi)
authorization
means an authorization issued by the Board under paragraph 142(1)(b) of the Act. (autorisation)
authorized inspector
means a person who is recognized under the laws of Canada or of a province as qualified to inspect boilers and pressure systems or the representative of a certifying authority who is qualified to carry out that function. (inspecteur autorisé)
barrier element
means a physical element that on its own does not prevent the flow of fluids but in combination with other barrier elements forms a well barrier. (élément de barrière )
barrier envelope
means an envelope of one or more barrier elements that prevents fluids from flowing unintentionally from the formation into the well-bore, another formation or the environment. (enveloppe de barrière)
certificate of fitness
means a certificate issued by a certifying authority in accordance with Part 3. (certificat de conformité)
certifying
authority means the American Bureau of Shipping, Bureau Veritas, Det norske Veritas or Lloyd’s Register Canada Limited. (autorité)
classification society
means a member of the International Association of Classification Societies that has recognized and relevant competence and experience in, and established rules and procedures for, the classification of fixed and floating structures, including vessels, used in oil or gas activities in locations with similar physical and environmental conditions. (société de classification)
commingled production
means the production of petroleum from more than one pool or zone through a common well where the production from each pool or zone is not measured separately. (production mélangée)
completion interval
means a section within a well that is prepared to permit
  • (a) the production of fluids from the well;
  • (b) the observation of the performance of the reservoir; or
  • (c) the injection of fluids into the well. (intervalle de complétion)
control centre
means a continuously staffed work area at which a control system that is critical to the operation of an installation or a pipeline, to safety and to the prevention of waste and pollution is located. (centre de contrôle)
control system
means any system, station or panel used to monitor the status and control the operation of the equipment used for or in support of the drilling for, or the production, processing or transportation of, petroleum, including any system, station or panel used to control the operation of an installation. (système de contrôle)
decommissioning and abandonment
means the process for the cessation of operations, the controlled abandonment of all wells and the retirement from service and the abandonment or removal of all installations, including their systems and equipment, as well as of pipelines and materials, as required by the legislation and regulations, the applicable authorization and any approved development plans. (désaffectation et abandon)
delineation well
has the same meaning as in subsection 122(1) of the Act. (puits de délimitation)
development well
has the same meaning as in subsection 122(1) of the Act. (puits d’exploitation)
diving installation
means a diving system installed on and integrated into an installation or vessel. (installation de plongée)
diving project
means any work or activity that is related to the exploration or drilling for, or the production, conservation, processing or transportation of, petroleum and that involves diving. (projet de plongée)
diving system
means the equipment required to execute a dive, including compression and decompression, and the equipment for rescue and recovery. (système de plongée)
drill site
means a location where a drilling rig is or is proposed to be installed. (emplacement de forage)
drilling installation
means a drilling unit or a drilling rig and the stable foundation on which it is installed — including an artificial island, an ice platform, a platform fixed to the seabed and any other foundation specifically used for drilling — and any accommodations area. (installation de forage)
drilling program
means a program for the drilling of one or more wells within a specified area and time through the use of one or more drilling installations, and includes any work or activity related to the program. (programme de forage)
drilling rig
means a rig that consists of the equipment used to conduct well operations and associated systems, including power, control and monitoring systems. (appareil de forage)
drilling riser
means the connection between a subsea blowout preventer and a mobile offshore platform. (tube prolongateur de forage)
drilling unit
means a fixed or mobile offshore platform, or a vessel used in any well operation, that is fitted with a drilling rig, including systems and equipment installed on the platform or vessel that are related to well operations and marine activities. (unité de forage)
environmental load
means a load imposed by climate, winds, waves, tides, currents, ice conditions, regional ice features such as sea ice and icebergs, snow, a seismic event or any other naturally occurring phenomenon. (charge environnementale)
environmental program
means a program pertaining to the measurement or statistical evaluation of the physical, chemical and biological elements of the lands, oceans or coastal zones, including winds, waves, tides, currents, precipitation, ice cover and movement, icebergs, pollution effects, flora and fauna, both onshore and offshore, human activity and habitation and any related matters. (programme environnemental)
exploratory well
has the same meaning as in subsection 122(1) of the Act. (puits d’exploration)
floating platform
means a column-stabilized mobile offshore platform, a surface mobile offshore platform or a fixed floating offshore platform, including a tension leg platform or a spar platform. (plate-forme flottante)
flow allocation procedure
means the procedure
  • (a) to allocate total measured quantities of petroleum and water produced from or injected into a pool or zone back to individual wells in a pool or zone where individual well production or injection is not measured separately; and
  • (b) to allocate production to fields that are using a common storage or processing facility. (méthode de répartition du débit)
flow calculation procedure
means the procedure to convert raw meter output to a measured quantity of petroleum or water. (méthode de calcul du débit)
flowline
means any line that is used to transport fluids between a well and the equipment for the production of petroleum located at a production site and the systems and equipment that are used in support of production, including all gathering lines but not including pipelines. (conduite d’écoulement)
flow system
means the flow meters, auxiliary equipment attached to the flow meters, fluid sampling devices, production test equipment, master meter and meter prover used to measure and record the rate and volumes at which fluids are
  • (a) produced from or injected into a pool;
  • (b) used as a fuel;
  • (c) used for artificial lift; or
  • (d) flared, vented or transferred from a production installation. (système d’écoulement)
formation flow test
means an operation
  • (a) to induce the flow of formation fluids to the surface of a well to procure reservoir fluid samples and determine reservoir flow characteristics; or
  • (b) to inject fluids into a formation to evaluate injectivity. (essai d’écoulement de formation)
functional load
means any construction load or operating load, other than an environmental load or accidental load. (charge fonctionnelle)
geoscientific program
means a program that involves any geological or geophysical work or activity. (programme géoscientifique)
geotechnical program
means a program that involves any work or activity undertaken to determine the physical properties of materials recovered from the seabed or shallow subsurface, in order to assess the suitability of the seabed or shallow subsurface, as the case may be, to support installations or any other structures. (programme géotechnique)
life-saving appliances
includes lifebuoys, survival craft, launching and embarkation appliances, marine evacuation systems and visual signals, as provided for in the LSA Code. (engins de sauvetage)
LSA Code
means the annex to International Maritime Organization Resolution MSC.48(66), International Life-Saving Appliance (LSA) Code. (recueil LSA)
load
includes a functional load, environmental load, accidental load and abnormal load. (charge)
major accidental event
means an unexpected or unplanned event or circumstance or series of unexpected or unplanned events or circumstances that may lead to the loss of more than one life or uncontrolled pollution. (événement accidentel majeur)
marine activity
means any activity related to stability, station-keeping and collision avoidance of floating platforms, and includes mooring, dynamic positioning and ballasting. (activité maritime)
mobile offshore platform
means a platform that is designed to operate in a floating or buoyant mode or that can be moved from place to place without major dismantling or modification, whether or not it has its own motive power. (plate-forme mobile extracôtière)
operations site
means a site where an authorized work or activity is carried out. (emplacement des opérations)
operator
means a person that holds an operating licence issued by the Board under paragraph 142(1)(a) of the Act and applies for or has been granted an authorization under paragraph 142(1)(b) of the Act. (exploitant)
physical and environmental conditions
means any physical, geotechnical, seismic, oceanographic, meteorological and ice conditions that might affect an authorized work or activity. (conditions physiques et environnementales)
pipeline
has the same meaning as in the Canadian Standards Association standard Z662, entitled Oil and gas pipeline systems, as it relates to offshore pipelines. (pipeline)
pollution
means the introduction into the environment of any substance or form of energy outside the limits applicable to an authorized work or activity. (pollution)
pressure system
means piping, pressure vessels, safety components and pressure components, including elements attached to pressurized parts such as flanges, nozzles, couplings, supports, lifting lugs, safety valves and gauges. (système sous pression)
production installation
means the equipment for the production of petroleum located at a production site, including separation, treating and processing facilities, equipment used in support of production, aircraft landing areas, storage areas or tanks and accommodations areas and any associated platform, artificial island, subsea production system, offshore loading system or equipment used to conduct well operations or systems and equipment related to marine activities. (installation de production)
production project
means a project for the purpose of developing a production site on, or producing petroleum from, a pool or field, including any work or activity related to the project. (projet de production)
production riser
means the connection between subsea production equipment and a production installation. (tube prolongateur de production)
production site
means a site where a production installation is or is proposed to be installed. (emplacement de production)
recovery of petroleum
means the recovery of petroleum under foreseeable economic and operational conditions. (récupération des hydrocarbures)
relief well
means a well drilled to assist in controlling a blowout in an existing well. (puits de secours)
reportable incident
means an event that resulted in any of the following occurrences or in which any of the following occurrences was narrowly avoided:
  • (a) loss of life;
  • (b) fire or explosion;
  • (c) collision;
  • (d) pollution;
  • (e) leak of a hazardous substance;
  • (f) loss of well control;
  • (g) impairment of a support craft or of any of the structural elements of an installation — or any system or equipment — critical to the safety of persons ;
  • (h) impairment of any of the structural elements of an installation — or any system or equipment — critical to environmental protection;
  • (i) implementation of emergency response procedures. (incident à signaler)
safety-critical element
means any system or equipment, including software and temporary or portable equipment, critical to the safety and integrity of an installation or critical to preventing the installation from polluting, including
  • (a) any system or equipment
    • (i) that is intended to prevent or limit the effect of a hazard that could cause a major accidental event, or
    • (ii) the failure of which could
      • (A) cause a hazard that could cause a major accidental event, or
      • (B) worsen the effects of such a hazard on the installation; and
  • (b) any software and temporary or portable equipment that affects the system or equipment referred to in paragraph (a).
subsea production system
means equipment and structures that are located on or below the seabed for the production of petroleum from, or for the injection of fluids into, a field under a production site, and includes production risers, flowlines and associated production control systems that are located upstream of the isolation valve. (système de production sous-marin)
support craft
means a vessel, vehicle, aircraft or other craft used to provide transportation or assistance to persons at an operations site. (véhicule de service)
waste material
means any garbage, refuse, sewage or waste fluids or any other useless material that is generated during the carrying out of any work or activity, including used or surplus drill cuttings and drilling fluid as well as produced water. (déchets)
watertight
means designed and constructed to withstand a static head of water without any leakage. (étanche)
well control
means the control of the movement of fluids into or from a well. (contrôle d’un puits)
well operation
means an operation related to the drilling, completion, recompletion, re-entry, intervention, workover, suspension or abandonment of a well. (travaux relatifs à un puits)
workover
means an operation on a completed well that requires removal of the tree or the tubing. (reconditionnement)
zone
means any stratum or any sequence of strata, including a zone that has been designated as such by the Board under paragraph 59(a). (couche)

Installation

(2) In these Regulations, any reference to an installation is a reference to a drilling installation, production installation or accommodations installation and, for the purposes of Part 3, also a reference to a diving installation.

Platform

(3) In these Regulations, the requirements that apply in respect of an installation also apply in respect of a platform.

Paragraph 142(4)(c) of Act

(4) The following definitions apply for the purposes of paragraph 142(4)(c) of the Act.

production facility
means the equipment for the production of petroleum located at a production site, including separation, treating and processing facilities, equipment used in support of production, aircraft landing areas, storage areas or tanks and accommodations areas, but does not include any associated platform, artificial island, subsea production system, drilling equipment or diving system. (installation de production)
production platform
means a production facility and any associated platform, artificial island, subsea production system, offshore loading system, drilling equipment, facilities related to marine activities and dependent diving system. (plate-forme de production)

Prescribed installation — section 198.2 of Act

(5) For the purposes of section 198.2 of the Act, any installation is a prescribed installation.

Incorporation by reference

2 (1) In these Regulations, any incorporation by reference of a document is an incorporation by reference of the most recent version of that document.

Bilingual documents

(2) Despite subsection (1), if a document that is incorporated by reference is available in both official languages, any amendment to it is incorporated only when the amended version is available in both official languages.

Experience, Training, Qualifications and Competence

Requirements

3 (1) An operator must ensure that any person to whom a duty is assigned or who carries out a work or activity under these Regulations has the necessary experience, training, qualifications and competence to carry out that duty, work or activity safely and in compliance with these Regulations.

Sufficient number

(2) The operator must ensure that the persons referred to in subsection (1) are sufficient in number and receive any necessary supervision to carry out that duty, work or activity in a manner that ensures safety.

PART 1

Management System

Development

4 An operator must develop a management system to reduce safety and environmental risks, prevent pollution and ensure the conservation of petroleum resources.

Requirements

5 (1) For the purposes of meeting the objectives set out in section 4, an operator must ensure that the management system meets the following requirements:

Documentation

(2) The operator must document the processes, policies and standards required by this section and ensure that they are readily accessible for consultation and examination.

Organization

(3) The documentation associated with the management system must be organized and set out in a logical fashion to allow for ease of understanding and efficient implementation.

Processes and procedures

(4) In this section, a reference to a process includes any procedures that are necessary to implement the process.

Human resources

6 (1) An operator must ensure that an organizational structure is put into place within which there are sufficient human resources to implement and continually improve the management system.

Accountable person

(2) The operator must designate an employee as accountable person for the management system and ensure they have the necessary authority over the human and financial resources that are required to implement and continually improve the system.

Name, position and contact information

(3) The operator must ensure that the name, position and contact information of the accountable person is submitted to the Board at the time the application for authorization is made and when a new designation is made under subsection (2) or each time any change is made to the name, position or contact information of the accountable person.

Signed statement

(4) The operator must ensure that the accountable person submits to the Board, within 30 days after the day on which they are designated, a signed statement accepting the responsibilities of their position as accountable person.

Implementation

7 (1) An operator must ensure that the management system is implemented before the commencement of any authorized work or activity.

Compliance

(2) The operator must ensure that the employees, employers, suppliers, service providers and other persons that are subject to the management system comply with the requirements of the management system.

Continual improvement

8 The accountable person referred to in subsection 6(2) must ensure that the management system is continually improved while the authorization remains valid.

PART 2
Authorization

Application

Documents and information

9 The application for an authorization must be accompanied by the following documents and information:

Safety plan

10 (1) An operator must develop a safety plan that sets out the procedures, practices, resources, sequence of key safety-related activities and monitoring measures that are necessary to safely carry out the proposed work or activity, including target levels of safety and measures for hazard management.

Documents and information

(2) The safety plan must include the following documents and information:

Environmental protection plan

11 (1) An operator must develop an environmental protection plan that sets out the procedures, practices, resources and monitoring measures that are necessary to protect the environment from the proposed work or activity, including target levels of safety and hazard management.

Documents and information

(2) The environmental protection plan must include the following documents and information:

Contingency plan

12 (1) An operator must develop a contingency plan that sets out the procedures (including emergency response procedures), practices, resources and monitoring measures that are necessary to effectively prepare for and mitigate the effects of any accidental event.

Documents and information

(2) The contingency plan must include the following documents and information:

Uncontrolled well

(3) In the case of a drilling program or a production project, the contingency plan must also include a description of the source control and containment measures to stop the flow from an uncontrolled well and to minimize the duration of a spill and its environmental effects, as well as the following documents and information:

Spill-treating agent

(4) If a spill-treating agent is being considered for use as a spill response measure, the contingency plan must include the following additional documents and information:

Assessment of efficacy

(5) The assessment of efficacy under paragraph (4)(a) must be carried out using oil obtained directly from an operations site or, if oil is not available from that operations site, using an oil that most closely resembles the oil expected to be obtained from the operations site and the assessment of efficacy must be repeated when oil becomes available from the operations site.

Methods and protocols

(6) The methods and protocols referred to in paragraph (4)(d) and the monitoring plan referred to in paragraph (4)(g) must conform to industry standards and best practices for spill-treating agent use, taking the local environment into account.

Definition of source control and containment equipment

(7) In this section, source control and containment equipment means the capping stack, containment dome, relief well drilling rig and any subsea and surface equipment, devices or vessels that are used to contain and control a spill source and minimize the duration of a spill and its environmental effects until well control has been regained.

Spill-treating agent — section 142.21 of Act

13 For the purpose of section 142.21 of the Act, the following are the factors that the Board must take into consideration to determine whether the use of a spill-treating agent is likely to achieve a net environmental benefit:

Field data acquisition program

14 In the case of a production project, an operator must develop a field data acquisition program that allows for the collection of sufficient pool pressure measurements, drill cutting and fluid samples, cores, well logs, formation flow tests, analyses and surveys to enable a comprehensive assessment of the field, the performance of development wells and pool depletion and injection schemes and provides for the quantity of samples and cores, the evaluation data and any associated analyses, surveys and reports that will be provided to the Board.

Flow system, calculation and allocation

15 (1) If the application for an authorization is in respect of a production project, the operator must submit to the Board for its approval the flow system, the flow calculation procedure and the flow allocation procedure that will be used to conduct the measurements referred to in sections 74 to 78.

Board approval

(2) The Board must approve the flow system, the flow calculation procedure and the flow allocation procedure if the applicant demonstrates that the system and procedures facilitate accurate measurements and allocate, on a pool or zone basis, the production from and injection into individual wells.

Decommissioning and abandonment plan

16 (1) An operator must, in the case of a drilling program or production project, develop a decommissioning and abandonment plan that includes the following documents and information:

Costs and financing or payment

(2) The operator must submit to the Board any update on the forecasted costs of decommissioning and abandonment and the manner in which the operator will finance or pay for the costs of decommissioning and abandonment, but, beginning not later than five years before the day on which the decommissioning and abandonment is forecasted to begin, the operator must submit to the Board annual updates of the forecasted costs and the manner in which the operator will finance or pay for those costs.

Well Approvals

Well operation

17 (1) Subject to subsection (2), an operator that intends to conduct a well operation must obtain a well approval.

Approval not necessary

(2) A well approval is not necessary to conduct a wire line, slick line, coiled tubing or similar operation through a tree located above sea level if the following conditions are met:

Approval application contents

(3) The application for a well approval must include the estimated cost breakdown of the well operation and the following information:

Well approval granted by the Board

(4) The Board must grant the well approval if the operator demonstrates that the well operation will be conducted safely, without waste or pollution and in compliance with these Regulations.

Definitions

(5) The following definitions apply in this section.

slick line
means a single steel cable that is used to run tools in a well. (câble lisse)
wire line
means a line that contains a conductor wire and that is used to run survey instruments or other tools in a well. (câble)

Well data acquisition program

18 In the case of a drilling program, an operator must develop a well data acquisition program that allows for the collection of sufficient pressure measurements, drill cutting and fluid samples, conventional cores, sidewall cores, well logs, formation flow tests, analyses and surveys to enable a comprehensive geophysical, geological and reservoir evaluation to be made and provides for the quantity of samples and cores, the evaluation data and any associated analyses, surveys and reports that will be provided to the Board.

Well verification scheme

19 (1) An operator must establish a well verification scheme based on criteria that it establishes to ensure that the design of any well is in accordance with industry standards and best practices to ensure its integrity throughout its life cycle.

Well ranking

(2) For the purposes of subsection (1), the operator must rank a well according to its level of risk and ensure that the well ranking is confirmed by an independent person.

Verification requirements

(3) The verification scheme must set out the verification requirements that are applicable to the design of a well according to its ranking and to any changes made to the design during its construction or operation that would affect any previously undertaken verification.

Additional verification requirements

(4) The operator must ensure that the verification requirements referred to in subsection (3) are carried out by an independent person that was not involved in the original design.

Suspension of well approval

20 (1) The Board may suspend a well approval if

Factors for suspension

(2) In deciding whether to suspend an approval in accordance with subsection (1), the Board must take into consideration the following factors:

Revocation of well approval

21 The Board must revoke a well approval if

Suspension or abandonment of well

22 If a well approval is revoked, the operator must ensure that the well is suspended or abandoned in accordance with Part 6.

Development Plan

Well approval — subsection 143(1) of Act

23 For the purposes of subsection 143(1) of the Act, a well approval relating to a production project is prescribed.

Concept safety analysis

24 (1) An operator must, at the time it applies for a development plan approval under section 143 of the Act, submit to the Chief Safety Officer a concept safety analysis.

Content of concept safety analysis

(2) The concept safety analysis must

Quantitative and qualitative risk assessments

(3) The target levels of safety must be based on risk assessments that are

Contents of risk assessment

(4) The operator must include in the risk assessment a description of the circumstances that will necessitate an update of the risk assessment, including changes in

Review of risk assessment

(5) The operator must update the risk assessment as often as necessary and at least once every five years throughout the life of the development to

Resource management plan — paragraph 143(3)(b) of Act

25 (1) For the purposes of paragraph 143(3)(b) of the Act, Part II of the development plan must include a resource management plan.

Contents of resource management plan

(2) The resource management plan must include a description and analysis of the following:

Organizational chart

(3) The resource management plan must also contain a description of the organizational structure for the proposed work or activity.

PART 3
Certificate of Fitness

Application

Prescribed installations — section 143.2 of Act

26 For the purposes of section 143.2 of the Act, a production installation, drilling installation, accommodations installation or diving installation is prescribed as an installation.

Requirements for Certification

Issuance of certificate — requirements and conditions

27 (1) Before a certifying authority issues a certificate of fitness in respect of an installation referred to in section 26,

Substitution — section 155 and subsection 210.07(1) of Act

(2) For the purposes of subparagraphs (1)(b)(ii) and (iii), the certifying authority may substitute for any equipment, methods, measures, standards or other things required by any regulation referred to in those subparagraphs, any other equipment, methods, measures, standards or other things the use of which is authorized by the Chief Safety Officer or the Chief Conservation Officer, as the case may be, under section 155 or subsection 210.07(1) of the Act.

Limitations

(3) The certifying authority must endorse on any certificate of fitness that it issues the details of any limitation on the operation of the installation that is necessary to ensure that the installation, including its systems and equipment, meets the requirements set out in paragraph (1)(b).

Conflict of interest — subsection 143.2(4) of Act

28 (1) For the purposes of subsection 143.2(4) of the Act, the following is the extent to which a certifying authority or one of its subsidiaries may participate in the design, construction or installation of an installation in respect of which a certificate of fitness is issued:

Notice of non-compliance

(2) The certifying authority must monitor for and identify any non-compliance with subsection (1) and must, without delay, inform the person that applied for the certificate and the Board of any non-compliance.

Certification plan

29 (1) A person that applies for a certificate of fitness must submit a certification plan to the Chief Safety Officer and to the certifying authority for the purposes of the approval of the scope of work under section 30.

Compliance

(2) The certification plan must demonstrate how compliance with subparagraph 27(1)(b)(ii) or (iii) will be achieved.

Other information

(3) Subject to subsection (4), the certification plan must also include the following documents and information:

Non-application

(4) Paragraphs (3)(b) to (d) do not apply in the case of a diving installation.

Scope of work

30 (1) A certifying authority must submit to the Chief Safety Officer for approval a scope of work that takes into consideration the certification plan.

Contents of scope of work

(2) The scope of work must include

Approval of scope of work

(3) The Chief Safety Officer must approve the scope of work if the Chief Safety Officer determines that

Certification period — five years

31 (1) A certificate of fitness is valid for five years if the certifying authority determines that the requirements of paragraph 27(1)(b) will be met for a period of at least five years.

Certification period — less than five years

(2) If the certifying authority determines that the requirements of paragraph 27(1)(b) can be met only for a period that is less than five years, the certificate of fitness is valid for the corresponding lesser period.

Expiry date

(3) The certifying authority must endorse on the certificate of fitness its expiry date, which is to be calculated from the date of its issuance.

Extension of period of certification

(4) The certifying authority may, on request of the person to which a certificate of fitness has been issued, extend the validity of that certificate of fitness for a period of up to three months, subject to the approval of the Chief Safety Officer.

Approval by Chief Safety Officer

(5) The Chief Safety Officer must approve the extension of the period of validity of the certificate of fitness if the extension does not compromise safety or the protection of the environment.

Applicable site or region

32 (1) A certifying authority must endorse on a certificate of fitness the site or region where the installation is to be operated.

Validity

(2) A certificate of fitness is valid for the operation of the installation at the site or in the region that is endorsed on it.

Renewal of certificate

33 The certifying authority must renew the certificate of fitness in relation to an installation before or on its expiry date if

Revalidation — scope of work

34 (1) Before renewing a certificate of fitness, the certifying authority must revalidate the scope of work in accordance with the criteria referred to in subsection 30(3) and make any modifications that are necessary.

Revalidation — new circumstances

(2) The Chief Safety Officer must request that the certifying authority revalidate the scope of work if new circumstances such as the following arise that have or could have a significant impact on the scope of work:

Revalidation approval

(3) The revalidated scope of work must be submitted to the Chief Safety Officer for approval under section 30.

Invalidity

35 (1) Subject to subsections (2) and (3), a certificate of fitness ceases to be valid if

Notice in writing

(2) At least 30 days before a determination is made under subsection (1), notice must be given in writing

Consideration of information

(3) Before making a determination under subsection (1), the certifying authority or the Chief Safety Officer, as the case may be, must consider any information in relation to that determination that is submitted by any person notified under subsection (2).

Change of Certifying Authority

Before initial certificate

36 (1) If the person that applies for a certificate of fitness decides to change the certifying authority in relation to an installation before the initial certificate of fitness is issued, the new certifying authority must undertake its own independent verification activities for the purposes of issuing the certificate of fitness.

After issuance of certificate

(2) If the person to which a certificate of fitness has been issued decides to change the certifying authority in relation to an installation, the person must

Transition plan implementation

(3) The person to which a certificate of fitness has been issued must ensure that the transition plan referred to in paragraph (2)(b) is implemented.

One certificate — one authority

(4) There must be no more than one certificate of fitness and certifying authority in relation to an installation at any given time.

Administrative Requirements

Organizational structure

37 The certifying authority must, without delay, notify the Board, the Federal Minister and the Provincial Minister of any changes to its organizational structure, including amalgamations and legal name changes.

Annual report

38 (1) The certifying authority must submit to the Board, the Federal Minister and the Provincial Minister an annual report on all of its certification activities.

Contents of annual report

(2) The annual report must contain the following information:

Monthly reports

(3) The certifying authority must submit a monthly report to the Board that describes the certification activities it carried out during the preceding month in respect of certificates of fitness that are applicable in the offshore area.

Information and documents to Board

(4) On the Board’s request, the certifying authority must submit to the Board any information obtained or documents generated in the course of carrying out its certification and verification activities.

Record retention

(5) The certifying authority must retain records, including the technical drawings, for any activity carried out during its certification or verification activities in respect of an installation for a minimum of seven years after the expiry date of the last certificate of fitness issued for that installation.

PART 4

General Requirements for Authorized Works and Activities

General

Safety and protection of environment

39 An operator must take all measures necessary to ensure safety and the protection of the environment during any authorized work or activity, including ensuring that

Physical and environmental conditions

40 An operator must ensure that observations of physical and environmental conditions and forecasts of those conditions, including sea states and ice movements, are obtained and recorded every day and each time there are substantial changes between the observations and the forecasts, and are maintained at an operations site.

Location of infrastructure or equipment

41 An operator must have data or information that accurately describes the location of any infrastructure or equipment on or attached to the seabed, including any abandoned installation or part of it.

Accessibility, storage and handling of consumables

42 An operator must ensure that explosives, fuel, spill-treating agents, spill containment products, safety-related chemicals, drilling, completion and well stimulation fluids, cement and other consumables are

Storage and handling of chemical substances

43 An operator must ensure that all chemical substances, including process fluids, fuel, lubricants, waste material, drilling fluids and drill cuttings generated at an installation, are stored and handled in a manner that does not create a hazard to safety or the environment.

Tampering with equipment

44 It is prohibited for any person to tamper with, activate without cause or misuse any equipment that is necessary for safety and the protection of the environment.

Cessation of work or activity

45 (1) An operator must ensure that any work or activity ceases without delay if it

Condition for resumption

(2) If the work or activity ceases, the operator must ensure that it does not resume until it can be done safely and without causing pollution.

Document Availability

Copy of authorization and other documents

46 (1) An operator must keep a copy of an authorization and other related approvals and plans required under the provisions of these Regulations or Part III of the Act at every operations site and ensure that they are readily accessible for consultation or examination.

Display

(2) The operator must ensure that a copy of the authorization and related approvals is displayed in a conspicuous location at every operations site.

Emergency response procedures and other documentation

47 An operator must ensure that a copy of the most current version of the emergency response procedures and any documentation necessary to carry out an authorized work or activity and to operate and maintain any installation or pipeline is

Plans

Implementation

48 (1) An operator must ensure that the safety plan referred to in section 10, the environmental protection plan referred to in section 11 and the resource management plan referred to in section 25 are implemented at the commencement of any work or activity and that the contingency plan referred to in section 12 is implemented as soon as an accidental event occurs or appears imminent.

Periodic updates

(2) The operator must ensure that the safety plan, environmental protection plan, resource management plan and contingency plan are periodically updated; however, the description of installations, vessels, systems and equipment provided in the safety plan and environmental protection plan in accordance with paragraphs 10(2)(c) and 11(2)(c), respectively, must be updated as soon as the circumstances permit after the modification, replacement or addition of any major component.

PART 5

Geoscientific Programs, Geotechnical Programs and Environmental Programs

Equipment, Materials and Property

Measures

49 An operator must ensure that

Certification

50 An operator must ensure that a competent and independent person has certified all equipment that is installed temporarily on a vessel to conduct a geoscientific program, geotechnical program or environmental program to ensure that the equipment is fit for the purposes for which it is to be used.

Damage to property

51 An operator must take all necessary measures to ensure that no property is damaged as a result of a geoscientific program, geotechnical program or environmental program.

Energy Sources

General requirements

52 (1) An operator must ensure that any energy sources used in a geoscientific program, geotechnical program or environmental program are

Electrical or electromagnetic energy source

(2) The operator must ensure that any electrical or electromagnetic energy source is equipped with circuit breakers on the charging and discharging circuits and with wiring that is adequately insulated and grounded to prevent current leakage and electrical shock.

Elimination of risk to divers

(3) The operator must ensure that, if an energy source is used, the program is conducted in a manner that eliminates all safety risks to divers, including by determining the minimum distances required to be maintained between the divers and the energy sources and ensuring compliance with those distances.

Testing of energy sources

53 (1) While a geoscientific program, geotechnical program or environmental program is being conducted, an operator must minimize energy source testing on the deck of an operations site.

Energy source activation

(2) Before the activation of an energy source for testing purposes, the operator must ensure that measures are implemented to protect persons at the operations site where the test will be conducted from exposure to any hazard associated with the energy source, including ensuring that

Primary Vessel

Classification

54 An operator must ensure that the primary vessel used in a geoscientific program, geotechnical program or environmental program holds a valid certificate of class issued by a classification society.

Destruction, Discard or Removal

Destroy, discard or remove from Canada

55 (1) It is prohibited for any person to destroy, discard or, subject to subsection (2), remove from Canada the following material or information that was acquired in the context of a geoscientific program, geotechnical program or environmental program unless the Board has approved it in accordance with subsection (3):

Exception

(2) The material or information referred to in subsection (1) may be removed from Canada without the approval of the Board for the purpose of being processed in a foreign country provided that the material or information is returned to Canada as soon as the processing is complete.

Approval

(3) The Board must, within 60 days after receiving an application for approval to destroy, discard or remove from Canada the material or information referred to in subsection (1), approve the application if the Board is satisfied that the material or information is not of much use or value.

Material or information

(4) The Board may, after receiving an application under subsection (3), require that the material or information, or a copy of the information, be provided to the Board within the period that it specifies.

PART 6

Drilling and Production

General

Definition of termination

56 In this Part, termination means that a well has been abandoned, suspended or completed.

Spacing and production rates

57 The Board may make orders respecting the allocation of areas, including the determination of the size of spacing units and well production rates, for the purpose of drilling for or producing petroleum.

Name, classification or status of well

58 The Board may give a name, classification or status to any well and may change that name, classification or status.

Pool, zone or field

59 The Board may

Evaluation of Wells, Pools and Fields

Implementation of data acquisition programs

60 (1) An operator must ensure that the field data acquisition program referred to in section 14 and the well data acquisition program referred to in section 18 are implemented in accordance with good oilfield practices.

Partial implementation of program

(2) If part of the field or well data acquisition program cannot be implemented, the operator must ensure that

Board approval

(3) If the operator demonstrates that the measures referred to in paragraph (2)(b) can achieve the goals of the field data acquisition program or the well data acquisition program, as the case may be, or are the only ones that can be taken in the circumstances, the Board must approve them.

Periodic updates

(4) The operator must ensure that the field data acquisition program is periodically updated.

Formation testing and sampling

61 An operator must ensure that any formation in a well is evaluated, tested and sampled to obtain data and samples from the formation if the Board determines that the data or samples would contribute substantially to the geological and reservoir evaluation.

Formation flow test

62 (1) An operator must ensure that no development well is put into production unless a formation flow test has been approved by the Board under subsection (5) and conducted in accordance with the Board’s approval.

Well operation

(2) If a development well is subjected to a well operation that might change its deliverability, productivity or injectivity, the operator must ensure that a formation flow test that has been approved by the Board under subsection (5) is conducted in accordance with the Board’s approval as soon as the circumstances permit after the well operation is ended and once the flow or injection conditions have stabilized in order to determine the effects of that operation on the well’s deliverability, productivity or injectivity.

Conditions

(3) The operator may conduct a formation flow test on a well drilled on a geological feature if, before conducting the test, it

Contribution to geological and reservoir evaluation

(4) The Board may require that the operator conduct a formation flow test on a well drilled on a geological feature, other than the first well, if the Board determines that the test would contribute to the geological and reservoir evaluation.

Approval of formation flow test

(5) The Board must approve a formation flow test if the operator demonstrates that the test will be conducted in a manner that ensures safety and protection of the environment and in accordance with good oilfield practices and that the test will enable the operator to

Samples and cores

63 An operator must ensure that all drill cutting and fluid samples and cores collected as part of the field data acquisition program referred to in section 14 and the well data acquisition program referred to in section 18 are

Remaining conventional core

64 (1) An operator must ensure that after any samples necessary for analysis or for research or academic studies have been removed from a conventional core, the remaining core, or a longitudinal slab that is not less than one half of the cross-sectional area of that core, is delivered to the Board.

Remaining sidewall core

(2) The operator must ensure that after any samples necessary for analysis or for research or academic studies have been removed from a sidewall core, the remaining core is delivered to the Board.

Notice before disposal

65 Before disposing of drill cutting or fluid samples, cores or evaluation data collected, an operator must ensure that the Board is notified in writing and given an opportunity to request delivery of the samples, cores or data.

Location of Wells

Reference for well depth

66 An operator must ensure that any depth in a well is measured from the rotary table of the drilling rig.

Directional and deviation surveys

67 An operator must ensure that

Well Integrity

Well control

68 (1) An operator must ensure that adequate procedures, materials and equipment are in place and used throughout the life cycle of the well to prevent the loss of well control.

Reliable well control equipment

(2) The operator must ensure that reliable well control equipment is in place to detect and control kicks, prevent blowouts and safely conduct all well operations.

Shallow hazards

(3) During well operations conducted without a riser, the operator must ensure that measures are taken to reduce the risk of shallow hazards while drilling.

Blowout preventer and barrier envelopes

(4) The operator must, after setting the surface casing, ensure that the blowout preventer is installed before drilling out the casing shoe and that there is a minimum of two independent barrier envelopes — each of which to be verified by the operator — in place throughout the life cycle of the well.

Barrier envelope failure

(5) If there is a failure in a barrier envelope, the operator must ensure that no other well operation takes place, other than those operations intended to replace or restore it, until the barrier envelope is replaced or restored.

Replacement or restoration of barrier envelope

(6) The operator must ensure that

Drilling fluid column

(7) The operator must ensure that, during well operations, one of the two barrier envelopes is the drilling fluid column, except when drilling under-balanced or if, when a completion or test string is run, the other barrier envelope has already been installed downhole and tested.

Pressure control equipment

(8) The operator must ensure that pressure control equipment associated with well operations is pressure-tested on installation and as often as necessary to ensure its continued safe operation.

Corrective measures

(9) If well control is lost or if safety, the protection of the environment or resource conservation is at risk, the operator must ensure that any necessary corrective measures to rectify the situation are taken without delay.

Definition of surface casing

(10) In this section, surface casing means the casing installed in a well to a sufficient depth, in a competent formation, to establish well control for the continuation of the drilling operations.

Casing and cementing

69 (1) An operator must ensure that a casing and wellhead system is designed so that, throughout the life cycle of the well,

Design requirements

(2) The operator must ensure that, during the design of the casing and wellhead system,

Casing depth

(3) The operator must ensure that the casing is installed at a depth that provides for adequate kick tolerance and safe well control.

Wellhead fatigue life

(4) The operator must ensure that the duration of well operations does not exceed the wellhead’s fatigue life.

Cement slurry

(5) The operator must ensure that the cement slurry is designed and installed so that, throughout the life cycle of the well,

Pressure testing and logging

(6) The operator must ensure that the cement integrity and placement is verified through pressure-testing and, if the cement is a common barrier element of the two barrier envelopes or confirmation of zonal isolation is required, also verified through logging.

Other measures

(7) Measures other than those referred to in subsection (6) may be used if the operator can demonstrate that the other measures provide equivalent levels of verification.

Cement design and slurry analysis

(8) The operator must ensure that the cement design is subjected to comprehensive laboratory testing and pre-cementing quality control under all foreseeable conditions that could have an impact on cementing so that the design provides the expected isolation and the cement can be efficiently installed.

Waiting on cement time

(9) The operator must ensure that, after cementing any casing or casing liner and before drilling out the casing shoe, the cement reaches the minimum compressive strength sufficient to support the casing and provide zonal isolation.

Casing pressure testing

(10) After installing and cementing the casing and before drilling out the casing shoe, the operator must ensure that the casing is pressure-tested to the value required to confirm its integrity for maximum anticipated operating pressure throughout the life cycle of the well.

Formation leak-off or integrity test

70 An operator must ensure that

Completion, testing and operation

71 (1) The operator of a well must ensure that

Segregated multi-pool well

(2) The operator of a segregated multi-pool well must ensure that

Definition of multi-pool well

(3) In this section, multi-pool well means a well that is completed in more than one pool.

Production tubing

72 An operator must ensure that the production tubing used in a well is designed and maintained for compatibility with the fluids to which it will be exposed, to withstand the maximum conditions, forces and stresses that may be placed on it and to maximize recovery of petroleum from the pool.

Safe operations and production

73 An operator must ensure that equipment and procedures are in place to recognize and control normal and abnormal operating conditions, to allow for safe and controlled well operations and production and to prevent pollution.

Measurements

Flow, volume and quantity

74 (1) Unless otherwise indicated in the approval under subsection 15(2), an operator must ensure that the following are measured:

Requirements for conducting measurements

(2) The operator must ensure that any measurements are conducted in accordance with the flow system, flow calculation procedure and flow allocation procedure approved under subsection 15(2).

Allocation of group production

75 (1) An operator must ensure that group production of oil, gas and water from wells and the injection of fluids into wells is allocated on a pro rata basis, in accordance with the flow system, flow calculation procedure and flow allocation procedure approved under subsection 15(2).

Allocation of production or injection volumes

(2) If a well is completed over multiple pools or zones, the operator must ensure that production or injection volumes for the well are allocated on a pro rata basis to the pools or zones in accordance with the flow allocation procedure approved under subsection 15(2).

Testing and maintenance

76 (1) An operator must ensure that

Notice

(2) The operator must ensure that a conservation officer is notified, as soon as the circumstances permit, of any modification to, malfunction or failure of any flow system component that may have an impact on the accuracy of the flow system and of the corrective measures taken.

Calibration

77 An operator must ensure that

Proration tests

78 In the case of a development well, the operator must ensure that sufficient proration tests are conducted to measure the rates at which fluids are produced from the well to permit an accurate determination of the allocation of oil, gas and water production on a pool and zone basis.

Production Conservation

Resource management

79 An operator must, in respect of the recovery of petroleum, ensure that

Commingled production

80 (1) It is prohibited for an operator to engage in commingled production except in accordance with an approval granted under subsection (2).

Approval by the Board

(2) The Board must approve commingled production if the operator demonstrates that it will maximize the recovery of petroleum.

Measurement and allocation

(3) If the operator engages in commingled production, it must ensure that the total volume and the rate of production of each fluid produced is measured and the volume from each pool or zone is allocated in accordance with the requirements set out in sections 74 to 78.

Pilot scheme

81 (1) An operator may develop and implement a pilot scheme that applies technology for the determination of commercial production of petroleum from a pool, field or zone accessible from a production installation that has an approved development plan in order to obtain information on reservoir, production or technology performance for the purpose of optimizing production performance under the approved development plan or determining whether the development plan requires an amendment for the purposes of optimization.

Duration

(2) The Board must establish the duration of the pilot scheme based on the time required to achieve the stated objectives.

Completion of pilot scheme

(3) On the completion of the pilot scheme, the operator must ensure that production activities related to the scheme are discontinued.

Prohibition against flaring or venting

82 It is prohibited for an operator to flare or vent gas unless

Venting limit

83 (1) An operator must ensure that the volume of gas vented under paragraph 82(a) is not greater than 15  000 standard m3 of gas per installation during a year.

Capture or venting of emissions

(2) The operator must ensure that the emissions of gas from the seals of a centrifugal compressor or reciprocating compressor at an installation are

Measure of flow rate of emissions

(3) The operator must ensure that the flow rate of emissions of gas released from vents referred to in paragraph (2)(b) is measured by means of a continuous monitoring device.

Requirements of continuous monitoring device

(4) The continuous monitoring device must

Centrifugal compressor

(5) The flow rate limit of emissions that are from the vents of a centrifugal compressor on an installation is

Reciprocating compressor

(6) The flow rate limit of emissions that are from the rod packings and distance pieces of a reciprocating compressor on an installation is

Corrective action

(7) If the alarm referred to in paragraph (4)(c) is triggered, the operator must ensure that corrective measures are taken as soon as the circumstances permit to reduce the flow rate to below or equal to the applicable flow rate limit.

Prohibition against oil burning

84 It is prohibited for an operator to burn oil unless

Spill-treating Agent

Small-scale test — paragraph 166.1(1)(b) of Act

85 (1) For the purposes of paragraph 166.1(1)(b) of the Act, the following are the requirements for a small-scale test of a spill-treating agent:

Conditions

(2) The following conditions must be met before a small-scale test is approved:

Net environmental benefit — subsection 166.1(3) of Act

(3) No small-scale test is to be approved if the Chief Conservation Officer has made a determination under subsection 166.1(3) of the Act regarding the net environmental benefit of that use of the spill-treating agent.

Oral or written approval

(4) Approval of a small-scale test must be provided orally or in writing, but if approval is provided orally, the Chief Conservation Officer must, as soon as the circumstances permit, provide to the operator written confirmation of the approval.

Factors — subsection 166.1(3) of Act

86 (1) For the purposes of subsection 166.1(3) of the Act, the following are the factors that the Chief Conservation Officer must take into account to determine whether the use of the agent is likely to achieve a net environmental benefit:

Industry standards and best practices

(2) The operator must ensure that the spill-treating agent is used in accordance with industry standards and best practices for spill-treating agent use, taking into consideration the local environment.

Equipment and materials

(3) The operator must ensure that all equipment and materials listed in paragraph 12(4)(f) are available and maintained in accordance with the manufacturers’ specifications and ready for use at all times.

Monitoring plan implementation

(4) The operator must implement the monitoring plan required under paragraph 12(4)(g) at the commencement of the use of a spill-treating agent in the case of a spill.

Chief Conservation Officer to be informed

(5) The operator must inform the Chief Conservation Officer of the spill-treating agent’s efficacy, the effects of its use on the environment and of any changes that may require a modification to its use.

Variation of approval

87 (1) The Chief Conservation Officer must vary its approval to use a spill-treating agent if new information indicates that a modification to its use is necessary for its use to likely achieve a net environmental benefit.

Revocation of approval

(2) The Chief Conservation Officer must revoke its approval if the new information indicates that, despite any modification to its use, its use will not likely achieve a net environmental benefit.

Well Termination

Conditions for suspension or abandonment

88 (1) An operator that suspends or abandons a well must ensure that the well can be readily located and is left in a condition that

Isolation before suspension and abandonment

(2) Before suspending or abandoning a well, the operator must ensure that all petroleum-bearing zones and discrete pressure zones have been isolated and verify the effectiveness of the isolation in accordance with the methods set out in its well approval application under paragraph 17(3)(e).

Additional condition for suspension

89 The operator that suspends a well must ensure that it is inspected and monitored to maintain its integrity and prevent pollution.

Additional condition for abandonment

90 The operator of a well must ensure that, on the abandonment of that well, the seabed is cleared of any material or equipment that might have an adverse effect on the marine environment or interfere with fishing activities or other uses of the sea.

Conditions for drilling installation removal

91 It is prohibited for the operator of a drilling installation to remove the drilling installation from a well or cause to have it removed unless

PART 7

Diving Projects

Definition of light dive craft

92 In this Part, light dive craft means a small vessel or secondary craft, equipped to deploy divers from a primary vessel.

Vessel used in diving project

93 An operator that conducts a diving project must ensure, in respect of a vessel used in the diving project, that

Dynamic positioning system

94 (1) An operator must ensure that the dynamic positioning system on a vessel used in a diving project

Design

(2) The design of the dynamic positioning system on a vessel used in a diving project must be based on numerical analysis and model testing to ensure that

Verification

(3) After the design of the dynamic positioning system is completed, the operator must ensure that a failure modes and effects analysis is conducted in order to verify that the dynamic positioning system meets the requirements set out in subsections (1) and (2).

Maintenance

(4) The dynamic positioning system must be maintained so that it continues to perform in accordance with its design specifications.

Light dive craft

95 (1) If a light dive craft is used for a diving project, an operator must ensure that

Equipment and system

(2) The operator must ensure that, when diving takes place from a light dive craft, the dive support vessel

PART 8

Installations, Wells, Pipelines and Vessels

Installations

General

Definitions

96 The following definitions apply in this Part.

air gap
means the clearance between the highest water or ice surface that occurs during extreme environmental conditions and the lowest exposed part of an installation not designed to withstand wave or ice impingement. (tirant d’air)
control station
means a work area that is not continuously staffed that provides an alternative location to a control centre and the minimum necessary control equipment to enable essential management of the facility or of specific key systems. (poste de contrôle)
damaged condition
means, with respect to a floating platform, the condition of the platform after it has suffered damage to the extent determined in accordance with the applicable recommendations of the MODU Code or, in the case of a platform that is not a mobile offshore drilling unit, the applicable rules of a classification society. (condition endommagée)
design service life
means the anticipated period during which any installation, including its systems or equipment, is to be used for its intended purpose, with anticipated maintenance but without substantial repair. (vie utile)
hazardous area
means an area on an installation where flammable, explosive or combustible mixtures are or are likely to be present in sufficient quantities and for sufficient periods of time to require special precautions to be taken in the selection, installation or use of machinery and electrical equipment to prevent a fire or explosion. (zone dangereuse)
IMO Resolution MSC.81(70)
means the annex to International Maritime Organization Resolution MSC.81(70), Revised Recommendation on Testing of Life-Saving Appliances. (résolution MSC.81(70) de l’OMI)
IS Code
means the annex to the International Maritime Organization Resolution MSC.267(85), International Code on Intact Stability, 2008. (recueil IS)
MODU Code
means the annex to the International Maritime Organization Resolution A.1023(26), Code for the Construction and Equipment of Mobile Offshore Drilling Units, 2009. (Code MODU)
operating limits
means the limits determined during the design of an installation, including its systems and equipment, a pipeline or vessel, as the case may be, within which it will continue to be fit for the purposes for which it is to be used, taking into account operating conditions, including changes in operating conditions, and all operating modes and the effect of those conditions and modes. (limites d’exploitation)
process vessel
means a heater, dehydrator, separator, treater or any other pressurized vessel used in the processing or treatment of produced petroleum. (cuve de traitement)
unattended installation
means an installation on which persons are not normally present and, in those instances when persons are present on the installation, their presence is for the purpose of performing operational duties, maintenance or inspections that will not require an overnight stay. (installation sans surveillance)

Safety and environmental protection

97 An operator must ensure that an installation, including its systems and equipment, is designed, constructed, installed, arranged and commissioned so that it is fit for the purposes for which it is to be used and can be operated safely without posing a threat to persons or the environment.

Design of installation — certification plan

98 An operator must ensure, for the purpose of meeting the requirement under section 97 in respect of design, that an installation, including its systems and equipment, is designed in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(c)(i).

Quality Assurance

Quality assurance program

99 (1) An operator must ensure that each phase of the life cycle of an installation, from its design up to and including its decommissioning and abandonment, is carried out in accordance with a quality assurance program to ensure that the installation, including its systems and equipment, is fit for the purposes for which it is to be used.

Requirements

(2) For the purpose of meeting the requirement under subsection (1), the operator must develop and implement a quality assurance program that meets the following requirements:

Documentation

(3) The operator must document the processes and policies required by this section and ensure that they are readily accessible for consultation and examination.

Organization

(4) The documentation associated with the quality assurance program must be organized and set out in a logical fashion to allow for ease of understanding and efficient implementation.

Processes and procedures

(5) In this section, a reference to a process includes any procedures that are necessary to implement the process.

Work Permits

Requirements

100 (1) An operator must ensure that a work permit that is required under this Part is issued, in either paper or electronic form, and sets out the following information:

Signatures

(2) The work permit must be signed by the person that issued it and every person involved in the work or activity to which it relates, to certify that they have read and understood its contents.

Operator obligations

101 (1) An operator must ensure that

Retention of copy

(2) The operator must retain a copy of each work permit issued for at least three years after the day on which the work or activity to which it relates is completed.

Design Analysis and Risk Assessment

Innovations

102 (1) An operator must ensure that any technology, including in materials, design methods, joining techniques and construction techniques, that has not been previously used in comparable situations is not used for the purposes of an installation unless

Technology qualification program

(2) The operator must develop a technology qualification program that sets out the performance monitoring and inspection measures that are necessary to determine the effectiveness of any technology referred to in subsection (1) that it intends to use.

Program implementation and update

(3) The operator must ensure that the program is implemented and periodically updated.

Physical and environmental conditions

103 (1) An operator must ensure that an installation is designed to withstand or avoid all foreseeable site-specific physical and environmental conditions, or any foreseeable combination of those conditions, without compromising its structural integrity or that of any of its systems or equipment that are critical to safety and the environment.

Criteria

(2) The operator must ensure that the design of an installation is based on criteria that are determined by using evidence-based regional and site-specific data, statistical analysis and modelling of physical and environmental conditions, including

Ice conditions

(3) The operator must ensure that an installation that is to be operated where ice conditions may exist is designed to

Redundancy

(4) The operator must ensure that there is redundancy included in any measures used for the purposes of paragraph (3)(a).

Certification plan

(5) The operator must ensure that an installation that is to be operated in a cold climate is designed and operated in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(c)(ii).

Design measures

(6) The design of an installation that is to be operated in a cold climate must include measures to

Design for intended use and location

104 (1) An operator must ensure that the structural components of an installation and any of its ancillary structures, including skids and modules, are designed for their intended use and location, taking into account

Analyses, tests, modelling and investigations

(2) The design of the structural components of an installation and any of its ancillary structures, including skids and modules, must be based on any analyses, model tests, numerical modelling and site investigations that are necessary to determine the behaviour of the installation and of the soils that support it or its mooring systems under all foreseeable operating, construction, transportation and installation conditions and under all foreseeable loads during the design service life of the installation, including any potential geohazards.

Design criteria

(3) The structural components of an installation and any of its ancillary structures, including skids and modules, must be designed to

Accidental loads

(4) For the purposes of paragraphs (3)(d) to (f) and (h), the design must take into account all credible accidental load scenarios, including collisions between the installation and a vessel or aircraft.

Conditions for safe operation and survival

105 Based on the results of any analyses, tests, modelling or investigations undertaken under subsection 104(2), the operator must ensure that

Risk assessment — fire, explosion and hazardous gas

106 (1) An operator must ensure that an assessment of fire and explosion risks and of risks associated with hazardous gas and its containment is conducted for any installation in order to identify

Elements for consideration

(2) For the purposes of paragraphs (1)(b) and (c), the assessments must take into consideration the following elements:

Reliability and availability

107 (1) An operator must demonstrate the reliability and availability of any system in an installation, the failure of which could cause or contribute to a major accidental event or the purpose of which is to prevent or mitigate the effects of the major accidental event, through a risk and reliability analysis using internationally recognized techniques.

Redundancies and measures

(2) The risk and reliability analysis must determine the redundancies and measures that are required to protect a system referred to in subsection (1) from failure, including any redundancies and measures required under this Part for that system.

Results of analysis

(3) The operator must ensure that the results of the risk and reliability analysis are reflected in the design of the installation, its systems and equipment and in any associated operating and maintenance manuals, including the operations manual referred to in section 153.

Installations — Design, Transportation, Arrangement and Other Requirements

Monitoring program for environment

108 (1) An operator must develop a monitoring program of the environment for the collection, in sufficient quantity, of data on physical and environmental conditions and the maintenance of that data to

Equipment

(2) For the purposes of subsection (1), the operator must ensure that the installation is equipped to observe, measure and forecast physical and environmental conditions, to record data on those conditions and to obtain from external sources any additional data on those conditions.

Availability of data

(3) The operator must ensure that the data referred to in subsection (1) that may have an impact on safety and the protection of the environment is documented and provided to those persons that request it.

Program implementation and update

(4) The operator must ensure that the monitoring program is implemented and periodically updated.

Maintenance

109 An operator must ensure that an installation is designed and equipped to allow for its inspection, monitoring, testing and maintenance, including

Materials for installations

110 (1) An operator must ensure that the materials used in an installation are

Definition of non-combustible

(2) In this section, non-combustible means, in respect of material, material that does not burn or give off flammable gases or vapours in sufficient quantity for self-ignition when heated to 750 °C.

Passive fire and blast protection

111 (1) An operator must ensure that an installation is designed to provide passive fire and blast protection.

Design of passive fire protection

(2) The design of the passive fire protection must

Divisions

(3) The operator must ensure that the installation is divided such that spacing and barriers protect against accidental events and loads identified in the risk assessment undertaken in accordance with subsection 106(1) or mitigate their effects.

Barriers — certification plan

(4) The operator must ensure that barriers are designed, arranged, installed and maintained in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(c)(iii).

Barriers — requirements

(5) Barriers must be designed, arranged, installed and maintained in order to

Barriers — technical drawings

(6) The level of protection that each barrier must provide is to be based on the results of the risk assessment undertaken in accordance with subsection 106(1) and the description and location of each barrier must be included on the technical drawings of the installation.

Barriers — penetrations and openings

(7) Barriers must not have any penetrations or openings unless

Barrier components

(8) The operator must ensure that barrier components are certified by a competent third party.

Bulkheads — production installation

(9) Unless the other combined features of a production installation can be demonstrated to provide at least the same level of protection, the operator must ensure that the following bulkheads are capable of preventing the passage of smoke and flame and to limit the unexposed face to an average temperature increase of 139 °C and a maximum temperature rise of 180 °C above the initial temperature following 120 minutes of exposure to a hydrocarbon fire:

Classification society rules

(10) The operator must ensure that the passive fire and blast protection for an installation that does not hold a valid certificate of class issued by a classification society is at least equivalent to the protection required under the rules of a classification society for a mobile offshore drilling unit.

Hazardous and non-hazardous areas

112 (1) An operator must ensure that an installation is divided into hazardous and non-hazardous areas, according to the type of works and activities that will be carried out and according to the associated hazards.

Classification of hazardous areas

(2) The operator must ensure that, after the risk assessment undertaken in accordance with subsection 106(1) is conducted, each hazardous area is classified according to a comprehensive and documented classification system.

Separation of areas

(3) The operator must ensure that hazardous areas of different classifications are separated from one another and from non-hazardous areas.

Direct access and openings

(4) The operator must ensure, if practicable, that there is no direct access or other opening between hazardous and non-hazardous areas and between hazardous areas of different classifications but, if not practicable, the operator must ensure that any direct access or opening is minimized.

Control of air flow between areas

(5) The operator must ensure that any access or opening between areas is designed to prevent uncontrolled air flow between the areas.

Piping systems

(6) The operator must ensure that piping systems are designed to prevent direct communication between hazardous and non-hazardous areas and between hazardous areas of different classifications.

Ventilation of enclosed hazardous areas

113 (1) An operator must ensure that any enclosed hazardous area on an installation is ventilated such that

Mechanical ventilation system

(2) If a mechanical ventilation system is used for the purposes of subsection (1), the operator must ensure that the air in the enclosed hazardous area is maintained at a pressure that is lower than the pressure of any adjacent non-hazardous area or hazardous area that is classified as less hazardous.

Air exhaustion from enclosed hazardous area

(3) The operator must ensure that all air exhausted from an enclosed hazardous area is let into an outdoor area that would be non-hazardous or classified as equal to or less hazardous than the enclosed hazardous area, had it not received the air from the enclosed hazardous area.

Ventilation pressure differential and functionality

(4) The operator must ensure that measuring devices are installed for each ventilation system of a hazardous area to monitor any loss of ventilation pressure differential and loss of functionality of that system and to activate audible and visual alarms at control points from which the system is monitored after a period of delay not exceeding 30 seconds, if such a loss occurs.

Positive overpressure relative to atmospheric pressure

(5) The operator must ensure that the main control centre and all accommodations areas on an installation

Power shut-off for mechanical ventilation system

(6) The operator must ensure that the power source for a mechanical ventilation system in a hazardous area, a work area in a non-hazardous area or an accommodations area is capable of being shut off from the control station and from a position that is outside the area being served by the ventilation system and will remain accessible during any fire that may occur within the area being ventilated.

Inlets and outlets of ventilation systems

(7) The operator must ensure that the main inlets and outlets of all ventilation systems are capable of being closed from a position that is outside the area being served by the ventilation system and will remain accessible during any fire that may occur within the area being ventilated.

Ventilation system in non-hazardous area

(8) The operator must ensure that any ventilation system serving a non-hazardous area is equipped with emergency devices in the event of a mechanical ventilation failure or hazardous gas detection, including

Ignition prevention

114 (1) In order to prevent the ignition of flammable, combustible or explosive substances on an installation, an operator must ensure that measures are taken to prevent the uncontrolled release or accumulation of those substances, including by ensuring that materials and equipment are properly arranged.

Design — systems and equipment

(2) The operator must ensure that any system or equipment that is to be used in a hazardous area is designed to control ignition sources and prevent fire and explosions taking into account the classification under subsection 112(2) of the area in which it is to be used.

Other requirements — equipment

(3) The operator must ensure that any equipment located in a hazardous area is rated for use in that area and installed, ventilated and maintained to ensure safe operation.

Safe distance operation

(4) The operator must ensure that any equipment that is not rated for use in a hazardous area is operated at a safe distance from any flammable, combustible or explosive substances and equipped with an automatic and manual means of deactivation in the event of fire or hazardous gas detection.

Equipment in event of emergency

(5) The operator must ensure that any equipment that is to remain in service in the event of an emergency associated with a gas release is rated as if it were located in a hazardous area.

Risk assessments

(6) For the purposes of meeting the requirements under subsections (1) to (5), the operator must ensure that any control measures identified in the risk assessment undertaken in accordance with subsection 106(1) are implemented.

Cargo tank

(7) The operator must ensure that the internal gas mixture inside a cargo tank is maintained outside the explosive limits and the systems associated with the cargo tank are designed to

Work permit

(8) A work permit is required for all hot work carried out on an installation.

Safe distances

(9) The work permit for hot work must set out safe distances between the hot work and any well or any flammable, combustible or explosive substances.

Safe means of escape, evacuation and rescue

115 An operator must ensure that an installation is equipped with a safe means of escape, evacuation and rescue, taking into account the results of the risk assessment undertaken in accordance with subsection 106(1) and comprehensive and documented safety studies.

Exits, access and escape routes

116 (1) An operator must ensure that, in any area where persons are normally present on an installation, there are at least two exits, each connected to an escape route, that provide safe, direct and unobstructed access to temporary safe refuges, muster areas, embarkation stations and evacuation points, as well as the means for persons to descend to the water.

Distancing — exits and connected escape routes

(2) The operator must ensure that the exits in each area referred to in subsection (1) are separated as far apart from each other as possible so that at least one exit and its connected escape route will be passable during an accidental event.

Location of escape routes

(3) The operator must ensure that the installation has escape routes on two of its sides.

Safe evacuation

(4) The operator must ensure that all escape routes from the accommodations area and the temporary safe refuge to the muster areas, embarkation stations and evacuation points are clearly marked and illuminated and provided with fire protection to allow for the safe evacuation of persons in a time frame determined in the safety studies referred to in section 115.

Size of escape routes

(5) The operator must ensure that the escape routes are of sufficient size to enable the efficient movement of the maximum number of persons who may need to use them, as well as unrestricted manoeuvring of fire-fighting equipment and stretchers, taking into account the maximum number of persons who can be accommodated on the installation during normal operations.

Temporary safe refuge

(6) The operator must ensure that the installation is equipped with a temporary safe refuge that, in the case of an emergency, including an accidental event, will

Areas required to remain safe

(7) The operator must ensure that the accommodations area, main control centre and any other area of an installation that is required to remain safe for persons to occupy during an emergency, including temporary safe refuges, is

Periodic verification

(8) The operator must verify on a periodic basis that the temporary safe refuge meets the requirements of subsections (6) and (7) and must record the findings resulting from the verification.

Life-saving appliances for installation

117 (1) An operator must ensure that an installation is equipped with life-saving appliances that

Loads

(2) The operator must ensure that life-saving appliances can withstand all loads to which they may be subjected when they are in use.

Space requirements and weight

(3) The operator must ensure that, in determining the number of persons any lifeboat, life raft or marine evacuation system can accommodate, the persons’ space requirements and weight while wearing immersion suits are taken into account.

Arrangement and selection

(4) The operator must ensure that the arrangement and selection of life-saving appliances are based on

Position

(5) The operator must ensure that copies of a plan showing the position of all life-saving appliances are posted on the installation, including in the main control centre and in any accommodations area and work area.

Lifeboats — availability

(6) The operator must ensure that the lifeboats on an installation

Lifeboats — specifications

(7) The operator must ensure that the lifeboats are totally enclosed or are free-fall lifeboats and that they are fire-protected.

Lifeboats — continuous communication

(8) The operator must ensure that the lifeboats are capable of being in continuous communication with the other lifeboats and vessels in the area.

Lifeboats — towing devices

(9) The operator must ensure that lifeboats are equipped with towing devices.

Life rafts

(10) The operator must ensure that the life rafts on an installation and of a combined capacity to accommodate the total number of persons on board the installation.

Continuous verification

(11) The operator must verify on a continuous basis that the lifeboats, life rafts and other life-saving appliances are available and in a condition to perform as expected and must record the findings that result from the verification.

Design for removal of installation

118 (1) An operator must ensure than an installation is designed taking into consideration its removal from the offshore area at the end of its design service life.

Requirement

(2) The design must include measures to facilitate the installation’s removal and to reduce risks to safety, adverse effects on the marine environment and interference with navigation and other uses of the sea, during and after the removal of the installation.

Exception

(3) Subsection (1) does not apply if the Board has approved, in the development plan, the abandonment or an alternative use of the installation.

Transportation and positioning

119 (1) An operator must ensure that the transportation and positioning of an installation, or a part of it, is conducted

Risk assessment

(2) Before an installation, or a part of it, is transported and positioned, the operator must ensure that the following requirements are met:

Systems and Equipment — Design, Installation, Commission and Other Requirements

Electrical system

120 (1) An operator must ensure that any electrical system on an installation is designed to avoid any abnormal conditions and faults that may endanger the installation or, if it is not possible to avoid them, to provide alerts of those conditions and faults and mitigate their effects.

Electrical system components

(2) The operator must ensure that all electric motors, lighting fixtures, electrical wiring and other electrical equipment on an installation are safe and reliable under all foreseeable operating conditions.

Device capable of monitoring insulation level to earth

(3) If a primary or secondary distribution system for electrical power, heating or lighting with no connection to earth is used on an installation, the operator must ensure that the system is equipped with a device that is capable of continuously monitoring the insulation level to earth and producing an audible or visual alarm to indicate abnormally low insulation values.

Main electrical power supply

(4) The operator must ensure that the main electrical power supply on an installation

Primary circuit shutdown

(5) The operator must ensure that the primary circuits from a power plant serving an installation are capable of being shut down from at least two separate locations, one of which must be the site of the power plant.

Control systems — certification plan

121 (1) An operator must ensure that a control system is designed in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(c)(iv).

Factors and requirements

(2) The design of a control system must meet the following requirements, taking into consideration human factors:

Control system hardware

(3) The operator must ensure that control system hardware is protected from circumstances that could adversely affect the performance of the system, including mechanical damage, excessive vibration, extreme temperatures or humidity levels, high electromagnetic field levels and electrical power disturbances and degradation caused by the physical and environmental conditions to which it may be exposed.

Wireless remote control system

(4) The operator must ensure that any wireless remote control system includes a means for

Alternative means of control

(5) The operator must ensure that control system functions that are required to ensure safety and are dependent on wireless communication links have an alternative means of control that can be activated as soon as the circumstances permit.

Control system testing

(6) Any equipment operated by a new, repaired or modified control system must not be put into operation until the operator ensures that the control system has been inspected and tested to confirm that it functions in the intended manner.

Documentation

(7) The operator must ensure that the most current version of documentation that describes the design, installation, operation and maintenance of the control systems is readily accessible for consultation and examination.

Integrated software-dependent control systems

122 (1) An operator must ensure that integrated software-dependent control systems, the failure or malfunction of which would cause a hazard to safety or the environment, are maintained to ensure their reliability, availability and security.

Safety-critical software

(2) The operator must ensure that any software that is a safety-critical element is

Modification to software features

(3) No modification to the features of the software referred to in subsection (2) is to be implemented unless the necessary internal approvals for the modification are obtained, including the approval of the installation manager.

Assessment and testing

(4) The operator must ensure that the modified software is not used until it is assessed and tested through the testing and validation process referred to in paragraph (2)(c).

Control measures

(5) The operator must ensure that control measures are implemented to protect the integrated software-dependent systems from any threat, including unauthorized access.

Emergency electrical power supply

123 (1) An operator must ensure that an installation has an emergency electrical power supply that is independent of the main electrical power supply such that the following systems and equipment continue to function in the event of a failure of the main electrical power supply:

Lights

(2) The operator must ensure that the installation is equipped with lights supplied by the emergency electrical power supply in the following locations:

Mechanically driven generator

(3) If the emergency electrical power supply is a mechanically driven generator, the operator must ensure that

Additional requirements

(4) The operator must ensure that the mechanically driven generator referred to in subsection (3) has redundancy in its starting capabilities and a dedicated source of fuel.

Design and maintenance

(5) The operator must ensure that the emergency electrical power supply, together with any transitional source of electrical power and self-contained battery system with which it may be equipped, are designed and maintained such that

Navigation lights and sound-signalling appliances

124 (1) An operator must ensure that an installation is equipped with the navigation lights and sound-signalling appliances that are required by the Collision Regulations as if that installation were a Canadian vessel to which those Regulations apply, unless compliance with the height and distance requirements of those Regulations is not possible, in which case the lights and appliances must be installed to maximize their audible and visual alerting capabilities for collision avoidance.

Radar

(2) The operator must ensure that an installation, other than an unattended installation, is equipped with radar for identifying hazards in proximity to the installation and that the radar is continuously monitored.

Communication system

125 (1) An operator must ensure that an installation is equipped with a communication system that has built-in redundancy and is capable of communicating continuously, including in an emergency, with

Radiocommunication systems

(2) Except in the case of an unattended installation, the operator must ensure that the following requirements are met in respect of any radiocommunication system on an installation:

General alarm system

126 (1) An operator must ensure that an installation is equipped with a general alarm system that is capable of alerting persons on the installation of any hazards to safety or the environment, other than fire or gas.

Additional requirements

(2) The operator must ensure that the general alarm system is

Alternative means of alert

(3) If a general alarm system is being inspected, maintained or repaired, the operator must ensure that there is an alternative means of alerting persons of the hazards referred to in subsection (1).

Gas release system

127 (1) An operator must ensure that an installation that includes process tanks, process vessels and piping has a gas release system that has a flaring system, a pressure relief system, a depressurizing system or a cold vent system.

Risk assessment — design

(2) The operator must ensure that the design of the gas release system is based on the results of the risk assessment undertaken in accordance with subsection 106(1).

Design

(3) The operator must ensure that the gas release system is designed

Oxygen

(4) The operator must ensure that the gas release system is designed and constructed to ensure that oxygen cannot enter the system during normal operations.

Location — system

(5) The operator must ensure that the gas release system is designed and located taking into account factors, including physical and environmental conditions, that affect the safe and normal flaring or emergency release of combustible liquid, gases or vapours so that when the system is in operation it does not damage the installation — or any other installation, vessel or support craft in proximity to it — or injure any person.

Control stations

(6) The operator must ensure that the control stations from which the gas release system is activated are located and spaced so that they remain protected and accessible for safe operation of the system.

Flaring system

(7) The operator must ensure that the flaring system and any associated equipment are designed to

Risk minimization — vents

(8) The operator must ensure that a vent that is used to release gas into the atmosphere without combustion is designed and located in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(d)(i).

Liquid removal

(9) The operator must ensure that any liquid, other than water, that cannot be safely and reliably burned at the flare tip of a gas release system is removed from the gas before it enters the flare.

Fire and gas detection system

128 (1) An operator must ensure that an installation is equipped with a fire and gas detection system.

Requirements

(2) The operator must ensure that the fire and gas detection system

Risk assessment — design

(3) The operator must ensure that the design of the fire and gas detection system is based on the results of the risk assessment undertaken in accordance with subsection 106(1).

Design

(4) The operator must ensure that the fire and gas detection system is designed to

Requirements

(5) The operator must ensure that the fire and gas detection system meets the following requirements:

Testing and maintenance

(6) For the purposes of the testing and maintenance of the fire and gas detection system, the operator must ensure that the following requirements are met:

Work permit

(7) A work permit is required for the testing and maintenance of the fire and gas detection system.

Management of override effects

(8) The override effects of the fire and gas detection system must be managed as a condition of the work permit referred to in subsection (7).

Leak repair

(9) The operator must ensure that any leak of hydrocarbon gas detected by the fire and gas detection system or by means of an auditory, olfactory or visual method — including the observation of the dripping of hydrocarbon liquids from the equipment component — and that must be repaired other than for the purposes of safety or resource conservation, is repaired as soon as the circumstances permit.

Emergency shutdown system

129 (1) An operator must ensure that an installation has an emergency shutdown system.

Requirements

(2) The operator must ensure that the emergency shutdown system is capable of

Studies and assessments — design

(3) The operator must ensure that the design of the emergency shutdown system is based on any studies or assessments that identify potential hazards and assess the risks associated with the identified hazards, including the risk assessment undertaken in accordance with subsection 106(1) and the risk and reliability analysis undertaken in accordance with section 107.

Design

(4) The operator must ensure that the emergency shutdown system is designed to

Shutdown logic

(5) The operator must ensure that the logic for the emergency shutdown system includes a hierarchy of shutdown levels, action sequences and timelines that are appropriate for the degree of risk posed by hazards identified in the studies and assessments referred to in subsection (3).

Additional requirements

(6) The operator must ensure that the emergency shutdown system meets the following requirements:

Testing and maintenance

(7) If the emergency shutdown system has override capabilities for the purposes of testing and maintenance activities, the operator must ensure that the following requirements are met:

Closure — subsurface safety valve

(8) In the case of a production installation, on initiation of the emergency shutdown system, the operator must ensure that any subsurface safety valve referred to in subsection 161(1) closes in not more than two minutes after the tree safety valve has closed, unless a longer delay is justified by the mechanical or production characteristics of the well.

Work permit

(9) A work permit is required for the testing and maintenance of the emergency shutdown system.

Management of override effects

(10) The override effects of the emergency shutdown system must be managed as a condition of the work permit referred to in subsection (9).

Fire protection systems and equipment

130 (1) An operator must ensure that an installation is equipped with fire protection systems and equipment to control and extinguish fires.

Certification plan

(2) The operator must ensure that the fire protection systems and equipment are designed, selected, operated, inspected, tested and maintained in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(d)(ii).

Design and selection

(3) The design and selection of fire protection systems and equipment, including suppression agents, must take into account their intended use and the results of the risk assessment undertaken in accordance with subsection 106(1).

Further requirements

(4) The operator must ensure that the fire protection systems and equipment include

Protection from damage

(5) The operator must ensure that the fire protection systems and equipment are protected from mechanical damage and damage caused by fire or explosion or physical and environmental conditions to which they may be exposed to remain capable of fulfilling their intended functions under all foreseeable operating conditions.

Fixed fire suppression system

(6) The operator must ensure that an automated fixed fire suppression system is installed in the accommodations area, in any hazardous area and in any other areas that require such a system based on the results of the risk assessment undertaken in accordance with subsection 106(1).

Fire pumps

(7) The operator must ensure that at least two dedicated, segregated and independently driven fire pumps supply a dedicated firewater ring main and each of those fire pumps is equipped with at least two independent starting devices.

Location and remote control activation

(8) The operator must ensure that the fire pumps are located as far as possible from equipment used for storing and processing petroleum, taking into account the results of the risk assessment undertaken in accordance with subsection 106(1), and are designed to include remote control activation.

Supply of firewater

(9) The operator must ensure that the fire pumps and piping and their valves are capable of providing a sufficient supply of firewater to any area on the installation, including if a segment of the firewater ring main is damaged.

Firewater system

(10) The operator must ensure that the firewater system is capable of operating continuously for a minimum of 18 hours.

Number and position of fire hydrants

(11) The operator must ensure that the number and position of fire hydrants and fire hose reels are such that at least two jets of water, not emanating from the same location, can reach any part of the installation where a fire may occur.

Portable fire extinguishing equipment

(12) In areas where it is not practical to use fire hydrants and fire hose reels, the operator must ensure that portable fire extinguishing equipment is readily available and accessible.

Activation at main control centre

(13) The operator must ensure that audible and visual alarms will activate at the main control centre on the initiation of any of the automated fixed fire suppression systems or on the loss of any firewater pressure.

Additional activation

(14) If the automated fixed fire suppression system creates a hazard to persons, the operator must ensure that audible and visual alarms automatically activate inside and outside the space that is being protected.

Unattended installations

(15) Paragraphs (4)(a) and (b) and subsections (6) to (11) do not apply to unattended installations.

Boilers and pressure systems — certification plan

131 (1) An operator must ensure that boilers and pressure systems are designed in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(d)(iii).

Design measures

(2) The design of boilers and pressure systems must include measures to

Method of design

(3) The design of boilers and pressure systems must

Loads and other factors

(4) The operator must ensure that boilers and pressure systems can withstand all combinations of loads, pressures, temperatures, fluids and substances to which they may be subjected during their design service life.

Materials for manufacturing

(5) The operator must ensure that the materials used for the manufacture of boilers and pressure systems are compatible with their operating environment and chemically resistant to the fluids they contain during their design service life.

Manufacturer’s documents and records

(6) The operator must ensure that the following documents and records are obtained from the manufacturer of the boilers and pressure systems:

Construction, installation, commissioning, inspection and testing

(7) The operator must ensure that boilers and pressure systems are constructed, installed and commissioned by competent persons and, before being put into operation, subjected to any inspections and tests, including non-destructive examination and proof tests, that are necessary to ensure their integrity and compliance with design specifications.

Inspection, testing and verification

(8) The operator must ensure that, after the installation of a boiler or pressure system, or after any modification or repair, including welding, is carried out on it, the boiler or pressure system is not put into operation until it is inspected and tested by an authorized inspector.

Maintenance and repair

(9) The operator must ensure that any boiler or pressure system is maintained and repaired in accordance with the operating procedures referred to in subsection (10).

Operating procedures

(10) The operator must ensure that operating procedures are developed for the boilers and pressure systems that inform users of operating hazards and indicate any special measures that must be taken to reduce risks when the boilers and pressure systems are being used, maintained or repaired.

Alteration of fitting

(11) It is prohibited for any person to alter, interfere with or render inoperative any boiler or pressure system fitting, except for the purpose of adjusting or testing the fitting.

Inspections

(12) The operator must ensure that the inspection of boilers and pressure systems is conducted by an authorized inspector.

Register

(13) The operator must keep a register of all boilers and pressure systems that includes the following documents and information:

Identification and information

(14) The operator must ensure that a boiler or pressure system is marked with any information that is necessary for its safe installation and operation and an identifier that permits reference to the documents and records referred to in subsection (6) and paragraphs (13)(e) and (f) regarding its manufacture, inspection, testing, maintenance and any repairs or modifications.

Verification

(15) The operator must ensure that all operating procedures developed in accordance with subsection (10) and the register referred to in subsection (13) are periodically verified by the certifying authority.

Non-application

(16) This section does not apply to any of the following:

Mechanical equipment — certification plan

132 (1) An operator must ensure that any mechanical equipment on an installation

Design

(2) The design of the mechanical equipment must take into account the following scenarios:

Operating instructions for internal combustion engine

(3) The operator must ensure that the basic operating instructions for an internal combustion engine provide details of stop, start and emergency procedures and are permanently attached to the engines.

Controls and manual shut-off devices

(4) The operator must ensure that the controls and manual shut-off devices are in a protected and readily accessible location that permits safe operation when an accidental event occurs that renders the associated equipment inaccessible.

Turbines and internal combustion engines

(5) The operator must ensure that turbines and internal combustion engines are

Exception

(6) Despite paragraph (5)(b), the turbines and internal combustion engines that are critical to emergency response, including emergency generators and fire pumps, must not be equipped with the safety devices referred to in that paragraph other than the safety devices to prevent major damage from overspeeding.

Operation of critical mechanical equipment

(7) The operator must ensure that mechanical equipment that is critical to the safety and propulsion of a floating platform will continue to operate safely and reliably at full rated power under static and dynamic angles of inclination specified by the rules of the classification society that certifies the platform under section 136.

Materials handling equipment

133 (1) An operator must ensure that all materials handling equipment is

Emergency slewing and lowering

(2) The operator must ensure that a crane with slewing capability is capable of retaining its slewing and lowering capability in emergency situations.

Identification and information

(3) The operator must ensure that all materials handling equipment is marked with an identifier that permits reference to information that is necessary to permit its safe operation, including any information and records regarding its design, construction, inspection, testing, maintenance and repair.

Inspection and proof test

(4) The operator must ensure that materials handling equipment is inspected and proof-tested by a competent third party to determine its rated capacity before it is put into operation if

Criteria for inspection and testing

(5) The operator must ensure that the inspection and proof-testing of materials handling equipment required under subsection (4) is done in accordance with criteria established by the manufacturer or applicable industry design and safety standards, including the frequency at which the equipment must be inspected and proof-tested to ensure its continued safe operation.

Rated capacity

(6) Following an inspection and proof test under subsection (4), the competent third party must certify in writing the rated capacity of the materials handling equipment.

Pedestal crane

(7) The operator must ensure that a pedestal crane meets the following requirements:

Crane hooks

(8) The operator must ensure that all crane hooks are equipped with positively engaged safety latches or equivalents that will prevent load shedding under any operating conditions.

Landing or taking off

(9) It is prohibited to move a crane in the vicinity of a landing area when an aircraft is landing or taking off.

Lifting device certification

(10) The operator must ensure that any materials handling equipment that lifts over 10 tonnes is certified by the certifying authority.

Subsea production system — certification plan

134 (1) An operator must ensure that a subsea production system is designed, constructed, installed, commissioned, operated, inspected, monitored, tested and maintained in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(c)(vi).

Design of subsea production system

(2) A subsea production system must be designed so that

Disconnectable riser

(3) The operator must ensure that a riser that is connected to a floating platform that has a disconnectable mooring system or dynamic positioning system is designed to be capable of safely detaching in any foreseeable physical and environmental conditions.

Riser disconnect

(4) The operator must ensure that, if risers are designed to disconnect in order to avoid foreseeable hazards, riser fluids may be safely displaced by water or isolated.

Riser integrity

(5) The operator must ensure that, if a riser is disconnected, its integrity is demonstrated through testing once reconnected and before being brought back into service.

Control of subsea production system

(6) The operator must ensure that a subsea production system is controlled from one location at any given time.

Failure modes and effects analysis

(7) The operator must ensure that any subsea production system is assessed through a failure modes and effects analysis.

Temporary or portable equipment

135 (1) An operator must ensure that any temporary or portable equipment used on an installation is fit for the purposes for which it is to be used.

Assessment of temporary or portable equipment

(2) Before any temporary or portable equipment is installed or brought into service on an installation, the operator must ensure that an assessment is conducted on the equipment and on its integration with other equipment and systems to determine its impact on existing safety-critical elements and on the quantitative risk assessment.

Certification plan

(3) The operator must ensure that temporary or portable equipment is managed in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(c)(vii).

Verification by certifying authority

(4) The operator must ensure that temporary or portable equipment that is a safety-critical element is, before being put into operation, verified by the certifying authority to confirm its suitability and safe placement and hook-up.

Platforms — Additional Requirements

Classification

136 An operator must ensure that a floating platform holds a valid certificate of class issued by a classification society according to the authorized work or activity to be carried out by the floating platform.

Air gap

137 An operator must ensure that a platform that is either founded on the seabed or column-stabilized has a sufficient air gap to operate safely under the maximum environmental load conditions to which it may be subjected.

Stability

138 (1) An operator must ensure that a floating platform is stable and can be operated safely — under intact or damaged conditions — in relation to all motions and loads to which it may be subjected, including by

Freeboard

(2) The operator must ensure that a floating platform has sufficient freeboard to operate safely under the maximum environmental load conditions to which it may be subjected.

Requirement — Codes

(3) The applicable recommendations concerning the stability and motion response of a floating platform in the MODU Code and Part B of the IS Code are mandatory and the operator must comply with them, except with respect to the recommendations for the inclining test for column-stabilized units under paragraphs 3.1.5.1 and 3.1.5.2 of the MODU Code, which are replaced by the requirements under subsections (5) and (6).

Gap analysis

(4) The operator must, every time the MODU Code is updated, undertake a gap analysis between the criteria in the updated version and the version that was used for the construction of the floating platform and any gaps must be risk-assessed and mitigation measures implemented, as required, by the operator.

Inclining test — first survey

(5) The operator must, in the case of a column-stabilized mobile offshore platform, ensure that a lightweight survey or inclining test is carried out during the first five-year classification society survey and that, if a lightweight survey is carried out and it indicates a change from the calculated light ship displacement of more than 1% of the operating displacement, an inclining test is carried out.

Subsequent five-year surveys

(6) During every subsequent five-year classification society survey, the operator must ensure, if the lightweight survey or inclining test during the first five-year survey demonstrated that the column-stabilized mobile offshore platform was maintained in accordance with the weight control program under paragraph 154(1)(c) and this is confirmed by the records referred to in paragraph 3.1.4 of the MODU Code, that light ship displacement is verified in operation by comparison of the calculated and observed draught. If the difference between the expected displacement and the actual displacement based on draught readings is more than 1% of the operating displacement, the operator must ensure that a lightweight survey is carried out in accordance with subsection (5).

Subsequent inclining tests

(7) Beginning with the third five-year classification society survey, the operator must ensure that an inclining test is carried out every 10 years.

Application — self-elevating mobile offshore platform

(8) Subsections (5) to (7) also apply in the case of a self-elevating mobile offshore platform.

Assessment — self-elevating mobile offshore platform

139 (1) An operator must, in the case of a self-elevating mobile offshore platform, ensure that a site specific assessment is conducted of the condition of the seabed, including seabed restraint, to ensure that the platform is stable and can be operated safely.

Requirements

(2) The operator must ensure that a self-elevating mobile offshore platform meets the following requirements:

Suspension of operations and well shut-in

(3) The operator must ensure that the works and activities on a self-elevating mobile offshore platform are suspended and that all wells associated with the platform are brought to a safe shut-in condition if

Corrective measures

(4) In the case of any of the situations referred to in subsection (3), the operator must ensure that the works and activities on the self-elevating mobile offshore platform remain suspended and that all wells associated with the platform remain in a safe shut-in condition until the cause of the situation has been investigated and corrective measures have been taken.

Ballast and bilge systems

140 (1) An operator must ensure that a floating platform is equipped with reliable ballast and bilge systems with the necessary redundancy in their components to

Requirement — Code

(2) The recommendations in the MODU Code concerning ballast and bilge systems are mandatory and the operator must comply with them.

Secondary ballast control station

(3) In the case of a column-stabilized mobile offshore platform, the operator must ensure that it is equipped with a secondary ballast control station that is equipped with

Location — secondary ballast control station

(4) The operator must ensure that a secondary ballast control station is located above the waterline in the final condition of equilibrium after flooding when the floating platform is in a damaged condition.

Failure modes and effects analysis

(5) An operator is not considered to be in compliance with this section unless the ballast and bilge systems have been assessed through a failure modes and effects analysis.

Watertight and weathertight integrity and freeboard — Codes

141 (1) The applicable recommendations concerning watertight and weathertight integrity and freeboard in the MODU Code and Part B of the IS Code are mandatory and the operator must comply with them.

Watertight subdivision

(2) The operator must ensure that the floating platform is designed with sufficient watertight subdivision to ensure preservation of reserve buoyancy and damage stability under all foreseeable conditions.

Load line certificate

(3) The operator must ensure that a floating platform meets the following requirements:

Watertight and weathertight appliances

(4) The operator must ensure that the arrangement and specification of watertight and weathertight appliances complies with the measures in respect of watertight and weathertight appliances described in the certification plan.

Water ingress

(5) The operator must ensure that a floating platform is designed with systems and equipment that provide for operating, monitoring and indicating — both locally and at the ballast control stations — the opening and closing of the watertight doors and hatches and for detecting and providing alerts of any water ingress into watertight spaces that are not designed to accumulate liquid.

Port lights

(6) The operator must ensure that the columns of a column-stabilized mobile offshore platform do not have port lights or similar openings.

Station-keeping

142 An operator must ensure that a floating platform is equipped with a mooring system or a dynamic positioning system to ensure station-keeping of the platform within its operating limits.

Mooring system design

143 (1) An operator must ensure that the design of a mooring system is based on analysis and model testing to ensure

Excursion limits

(2) The operator must ensure that the excursion limits of a floating platform are established based on the analysis and model testing required under subsection (1).

Loss of station-keeping or failure

(3) The operator must ensure that a floating platform has systems and processes to continuously detect loss of station-keeping or the failure of any mooring system component.

Measures

(5) The operator must ensure that measures are taken to ensure that the mooring system continues to perform in accordance with its design specifications, including

Disconnectable mooring system

144 (1) If a floating platform has a disconnectable mooring system, the operator must ensure that the system is designed to ensure that disconnection can be accomplished in a controlled manner without creating a risk of drift-off.

Certification plan

(2) The operator must ensure that a disconnectable mooring system is designed and maintained in accordance with the measures included in the certification plan referred to in subparagraph 29(3)(d)(iv).

Primary and backup systems

(3) The operator must ensure that a disconnectable mooring system includes a primary system and a backup system to achieve disconnection, both of which can be operated locally or from a remote location.

Floating platform capacity

(4) The operator must ensure that a floating platform that has a disconnectable mooring system is capable of

Criteria and procedures for disconnect

(5) The operator must ensure that criteria and procedures for disconnection are developed for all credible disconnection scenarios, including procedures for monitoring environmental conditions and providing alerts for worsening conditions that may require disconnection.

Disconnection and reconnection

(6) The operator must ensure that a disconnectable mooring system is capable of

Periodic verification of disconnect capability

(7) The operator must periodically verify the disconnect capability of the disconnectable mooring system and must record the findings resulting from the verification.

Excursion limits exceeded

(8) The operator must ensure that the emergency disconnection referred to in paragraph (6)(b) is initiated if the floating platform exceeds the excursion limits established under subsection 143(2).

Dynamic positioning system design

145 (1) An operator must ensure that the design of the dynamic positioning system for a floating platform

Excursion limits

(2) The operator must ensure that the excursion limits of a floating platform are established based on the numerical analysis and model testing required under paragraph (1)(a).

Disconnect system

146 (1) An operator must ensure that a floating platform with a dynamic positioning system has a disconnect system capable of

Demonstration

(2) The operator must periodically demonstrate by means of a trial or performance test that the disconnect system meets the requirements under subsection (1).

Excursion limits exceeded

(3) The operator must ensure that the emergency disconnection referred to in paragraph (1)(b) is initiated if the floating platform exceeds the excursion limits established under subsection 145(2).

Decisions and exemptions

147 For any floating platform that is registered outside Canada, the operator must

Asset Integrity

Requirements

148 An operator must ensure that all installations, including their systems and equipment, are inspected, monitored, tested, maintained and operated to ensure safety and the protection of the environment, prevent waste and continue to perform in accordance with their design specifications under the maximum load and operating conditions to which they may be exposed.

Non-destructive examination

149 An operator must ensure that a non-destructive examination of critical joints and structural parts of an installation is conducted at least once in every five-year period after the date of the last inspection or more often as required to ensure the continued safe operation of the installation.

Winterization

150 An operator must ensure that the winterization of an installation is completed in accordance with subsection 103(5) before any cold climate operation is conducted.

Corrosion management

151 (1) An operator must ensure that the corrosion of any equipment, including process vessels, and of any piping, valves, fittings and structural elements that are part of an installation, the failure of which as a result of the corrosion — including corrosion due to exposure to a sour environment — would cause a safety or environmental hazard, is prevented and managed throughout the life cycle of the installation.

Corrosion management program

(2) The operator must develop a corrosion management program that sets out the measures that are necessary to prevent critical failures resulting from corrosion-related degradation and ensure the continued integrity of safety-critical elements.

Program requirements

(3) The program must

Program implementation and update

(4) The operator must ensure that the program is implemented and periodically updated taking into account the data and analysis referred to in paragraph (3)(e).

Operation and Maintenance

Limits and requirements

152 An operator must operate any installation, including its systems and equipment, in accordance with any limitations set out in the certificate of fitness under subsection 27(3), any requirements under this Part and the operations manual referred to in section 153.

Operations manual

153 (1) An operator must develop, adhere to and maintain an operations manual that contains or makes reference to the following documents and information:

Additional information — floating platform

(2) In the case of a floating platform, the operations manual must also contain

Additional information — mobile offshore platform

(3) In the case of a mobile offshore platform, the operations manual must also contain

Programs

154 (1) An operator must develop the following programs to ensure the continued integrity of an installation, including its systems and equipment, from the time the installation is commissioned until it is abandoned or removed from the offshore area:

Program implementation and update

(2) The operator must ensure that the programs are implemented and periodically updated.

Maintenance program

155 (1) The maintenance program must set out the inspection, monitoring, testing and maintenance policies and procedures for an installation, including its systems and equipment, that are necessary to ensure safety, protect the environment and prevent waste.

Requirements

(2) The maintenance program must

Preservation program

156 (1) The preservation program must set out the measures that are necessary to ensure the integrity of equipment that is taken out of service and stored for future use.

Periodic inspection

(2) The program must provide for the periodic inspection of the stored equipment to verify its integrity and ensure that it is fit for the purposes for which it is to be used if it is brought into service.

Weight control program

157 The weight control program must set out the measures that are necessary to ensure that the weight and centre of gravity of each installation are kept safely within the installation’s operating limits.

Notice of repair, replacement and modification

158 (1) No person to which a certificate of fitness has been issued is to make a repair, replacement or modification to a safety-critical element, or bring on board the installation any equipment that would change the design, performance or integrity of a safety-critical element, without notice to the certifying authority and the Chief Safety Officer.

Approval

(2) Subject to subsection (3), a person to which a certificate of fitness has been issued must ensure that the approval of the certifying authority is obtained before any repair or modification is undertaken under subsection (1).

Verification

(3) The person to which a certificate of fitness has been issued must ensure that a safety-critical element that has been repaired or modified is not put into operation until the certifying authority has verified it and

Emergency repair or modification

(4) In an emergency, subsections (2) and (3) do not apply if the installation manager considers that the delay required to comply with the requirements under those subsections endangers persons on the installation or the environment.

Verification after emergency

(5) A safety-critical element that is repaired or modified in an emergency must be verified by the certifying authority in accordance with subsection (3) as soon as the circumstances permit.

Non-application

(6) This section does not apply in the case of an adjustment made to or the testing of a boiler or pressure system fitting.

Wells

Drilling fluid systems

159 An operator must ensure that

Drilling riser

160 (1) An operator must ensure that every drilling riser is capable, throughout the duration of a well operation, of

Drilling riser support

(2) The operator must ensure that every drilling riser is supported in a manner that effectively compensates for any loads caused by the motion of the installation, the drilling fluid or the water column.

Drilling riser analysis

(3) The operator must ensure that a drilling riser analysis is conducted and, in the case of a floating platform that will use a dynamic positioning system, that a weak-point analysis of the drilling riser is also conducted.

Fail-safe subsurface safety valve

161 (1) An operator must ensure that a completed development well is equipped with a fail-safe subsurface safety valve that can be operated from the surface.

Requirements

(2) The operator must ensure that the subsurface safety valve

Fail-safe safety valve

(3) The operator must ensure that a completed development well that has gas lift, injection or production capabilities in the A-annulus is equipped with a fail-safe safety valve on the A-annulus.

Requirements

(4) The operator must ensure that the fail-safe safety valve on the A-annulus is designed, installed, tested, maintained and operated to prevent uncontrolled well flow when activated.

Well tubulars, trees and wellheads

162 (1) An operator must ensure that well tubulars, trees and wellheads are operated in accordance with good engineering practices.

Sour environment

(2) The operator must ensure that any well tubulars, trees or wellheads that may be exposed to a sour environment are capable of operating safely in that environment.

Safe and efficient operation

(3) The operator must ensure that the wellhead and tree equipment, including any valves, are designed and maintained to operate safely and efficiently throughout the life cycle of the well under all loads to which it may be subjected.

Formation flow test equipment

163 (1) An operator must ensure that the equipment used in a formation flow test is designed to safely control well pressure, evaluate the formation and prevent pollution.

Rated working pressure

(2) The operator must ensure that the rated working pressure of formation flow test equipment upstream of and including the well testing manifold exceeds the maximum anticipated shut-in pressure.

Overpressure

(3) The operator must ensure that the equipment downstream of the well testing manifold is protected against overpressure.

Downhole safety valve

(4) The operator must ensure, in the case of a development well, that the formation flow test equipment includes a downhole safety valve that permits closure of the test string above the packer.

Formation flow test program

(5) The operator must ensure, in the case of a formation flow test program for an exploratory well or a delineation well, that a downhole safety valve is installed before the tests are conducted unless

Subsea test tree

(6) The operator must ensure that any formation flow test equipment used in testing a well that is drilled with a floating drilling unit has a subsea test tree that is equipped with

Pipelines

Pipeline integrity — standard

164 (1) An operator must ensure that a pipeline is designed, constructed, installed, operated and maintained in accordance with the Canadian Standards Association Standard Z662 entitled Oil and Gas Pipeline Systems, as it relates to offshore pipelines.

Integrity management program

(2) The operator must ensure that the pipeline system integrity management program set out in that standard is implemented and periodically updated.

Monitoring of Installations, Wells and Pipelines

Monitoring of systems

165 (1) An operator must ensure that an installation is equipped with a central monitoring system in the main control centre to monitor all systems the failure of which may cause or contribute to an accidental event or waste.

Management of associated systems

(2) The operator must ensure that the alarm, safety, monitoring, warning and control functions associated with the systems that are monitored under subsection (1) are managed to prevent reportable incidents and waste.

Affected persons informed

(3) The operator must ensure that all affected persons are informed when a function referred to in subsection (2) is suspended and when it is returned to service.

Suspension of related system

(4) When a function referred to in subsection (2) is suspended or found to be impaired, the operator must ensure that the use of any related system is also suspended until

Notice of deterioration — Chief Safety Officer

166 (1) An operator must, without delay, notify the Chief Safety Officer of any deterioration of an installation, including its systems or equipment, a pipeline, well, vessel or support craft that could adversely affect safety or the environment.

Notice of deterioration — certifying authority

(2) If any installation, system, equipment, pipeline or part of a well referred to in subsection (1) is within the scope of work referred to in section 30, the operator must also, without delay, notify the certifying authority of the deterioration.

Impairment rectification

(3) The operator must ensure that any impairment in an installation, including in its systems or equipment, as well as in any pipeline, well, vessel or support craft that could adversely affect safety or the environment is rectified without delay.

Mitigation measures

(4) If it is not possible to rectify the impairment without delay, the operator must

Non-application

(5) Subsections (3) and (4) do not apply in the case of safety-critical elements.

PART 9

Support Operations

Support craft

167 An operator must ensure that all support craft are capable of safely providing necessary support functions in the foreseeable physical and environmental conditions prevailing in the area in which they operate.

Support craft — availability and equipment

168 (1) An operation must ensure, in the case of an installation on which persons are normally present, that the following requirements in respect of support craft are met:

Required distance exceeded

(2) If the support craft is located at a distance that exceeds the distance referred to in paragraph (1)(a), both the installation manager and the person in charge of the support craft must log this fact and the reason why the distance or time was exceeded.

Vessel master

(3) During any activity or situation referred to in paragraph (1)(b), or any other activity or situation that presents an increased level of risk to the safety of the installation, the vessel master must, under the direction of the installation manager, keep the craft in close proximity to the installation, maintain open communication channels with the installation and be prepared to conduct rescue operations.

Rescue boat

169 An operator must ensure that, in the event of an emergency, a rescue boat is available and ready for use for any vessel that is used in a geoscientific program, geotechnical program, environmental program, diving project or any construction activities.

Safety zone — installation

170 (1) The safety zone around an installation consists of the area within a line that encloses the installation and is drawn at a distance of 500 m from the outer edge of the installation or, if any component of the installation extends beyond that edge, from the outer limit of the component that extends furthest from that edge.

Safety zone — vessel

(2) The safety zone around a vessel engaged in a geoscientific program, geotechnical program, environmental program or diving project consists of the area within a line that encloses the vessel and any of its attached equipment and is drawn at a distance that minimizes risks to safety, the environment and property located nearby, including fishing gear or fishing vessels.

Entry into safety zone

(3) A support craft must not enter the safety zone without the consent of the installation manager or the person in charge of the operations site.

Safety zone boundaries

(4) The operator must ensure that persons who are in charge of any aircraft or vessel that is approaching the safety zone are notified of the safety zone boundaries, the facilities within the safety zone and any related hazards.

Landing area

171 (1) An operator must ensure that the aircraft landing area on an installation or vessel, including its equipment, is designed to ensure safety and the protection of the environment and to prevent an incident or damage from the use of an aircraft.

Procedures and training program

(2) The operator must ensure the establishment of procedures associated with the support of aircraft operations, including procedures for emergency response, and a training program for personnel for those purposes.

Requirements

(3) The operator must ensure that the landing area

Fuel storage tanks

(4) The operator must ensure that any fuel storage tanks that are in proximity to a landing area are stored safely and protected from damage, impact or fire.

Aircraft service provider

172 An operator must ensure that, before the start of any operations that require the use of an aircraft, the aircraft service provider has accepted in writing all conditions with respect to the use of the equipment on any landing area, procedures associated with the support of aircraft operations, including the procedures for emergency response, and the training program for personnel.

Classification

173 An operator must ensure that any support or construction vessel to be used in conjunction with an installation holds a valid certificate of class issued by a classification society according to the work or activity to be carried out by it.

PART 10

Notice, Records, Reports and Other Information for Authorized Works and Activities

General

Definition of shotpoint

174 In this Part, shotpoint means the surface location of a seismic energy source.

Reportable incidents

175 (1) An operator must notify the Board of a reportable incident as soon as the circumstances permit, but not later than 24 hours after becoming aware of the incident.

Investigation

(2) The operator must ensure that

Accessibility of records

176 An operator must ensure that any records that are necessary to support operational requirements and the requirements of these Regulations are readily accessible to the Board for examination.

Critical information

177 (1) An operator must ensure that records are kept of any information critical to safety, the protection of the environment or the prevention of waste, including information on

Record retention periods

(2) The operator must retain the records referred to in subsection (1) for the following periods:

Safety report

178 (1) An operator must ensure that a safety report that relates to an authorized work or activity conducted in a given calendar year is submitted to the Board within 90 days after the day on which the work or activity is concluded or suspended or, in the case of a work or activity that will continue into the following calendar year, a safety report that relates to the work or activity conducted in the preceding calendar year is submitted to the Board not later than March 31st of that following calendar year.

Requirements

(2) The safety report must include

Annual reports

179 An operator must ensure that the Board is made aware, at least once a year, of any report containing relevant information regarding applied research work or studies that the operator has participated in, funded or commissioned concerning the operator’s authorized works and activities in relation to safety, the protection of the environment or resource management, and that a copy of the report is submitted to the Board on request.

Geoscientific, Geotechnical and Environmental Programs

Notice — key dates

180 When any geoscientific program, geotechnical program or environmental program is commenced, concluded, suspended or cancelled by an operator, the operator must, without delay, notify the Board in writing of the date of the commencement, conclusion, suspension or cancellation of the program.

Weekly status reports

181 (1) An operator must ensure that weekly reports are submitted to the Board on the status of field work carried out in relation to any geoscientific program, geotechnical program or environmental program, from the commencement of the program until its conclusion, suspension or cancellation.

Content of reports

(2) The weekly status reports must include the following documents and information:

Environmental report — programs

182 An operator must ensure that an environmental report that includes the following documents and information is submitted to the Board within 90 days after the day on which a geoscientific program, geotechnical program or environmental program is concluded or suspended:

Final reports

183 (1) An operator must ensure that a final operations and data processing report and a final interpretation report are submitted to the Board with the acquired data referred to in subsection (4), as applicable, within 12 months after the day on which any geoscientific program, geotechnical program or environmental program is concluded unless a longer period has been agreed to in writing by the Board.

Content of final operations and data processing report

(2) The final operations and data processing report must contain the following documents and information, as applicable:

Content of final interpretation report

(3) The final interpretation report must contain the following documents and information, as applicable:

Acquired data

(4) The following are the acquired data that must accompany the final reports, as applicable:

Incorporation of previous data

(5) In submitting a map referred to in paragraph (3)(b), the operator must incorporate any previous data collected by the operator that are related to the area covered by the map and that are of a type similar to the data from which the map was produced.

Final interpretation report not required

184 (1) An operator that has conducted a geoscientific program does not need to submit the final interpretation report required by subsection 183(3) if the data acquired from the geoscientific program are made available to the public for purchase or use under licence.

Final interpretation report required

(2) If the operator ceases to make data available for purchase or use under licence, the operator must ensure that, within 12 months after the day on which the operator ceased to make the data available, the final interpretation report is submitted to the Board.

Data purchases

185 (1) A purchaser of data referred to in subsection 184(1), acquired in an area that is subject to an interest, as defined in section 49 of the Act, must submit to the Board the final interpretation report required by subsection 183(3) if the costs of the purchase of the data are credited against a deposit or other costs in relation to the interest.

Reports from data purchaser

(2) If the purchaser has reprocessed or reinterpreted the data, and if the costs of the reprocessing or reinterpretation are to be credited against a deposit or other costs of the interest, the purchaser must submit to the Board the final operations and data processing report required by subsection 183(2), the final interpretation report required by subsection 183(3) and the accompanying data required by subsection 183(4).

Timing of submissions

(3) The data and reports required under subsections (1) and (2) must be submitted by the purchaser to the Board before the costs referred to in those subsections are credited.

Notice to Chief Conservation Officer

(4) A person who has submitted a report referred to in this section must, in respect of data that pertain to shotpoints or the location of stations, notify the Chief Conservation Officer, without delay, of any errors, omissions or corrections identified in or made to the data after the report is submitted.

Drilling and Production

Reference

186 When submitting any information to the Board about a well, pool, zone or field under these Regulations, an operator must refer to each by the name given to it under section 58 or paragraph 59(b).

Results, data, analysis and schematics

187 (1) An operator must ensure that a copy of the final results, data, analyses and schematics obtained from the following sources is submitted to the Board:

Submission within 60 days

(2) Unless otherwise agreed to in writing by the Board, the operator must ensure that the copy is submitted within 60 days after the day on which any activity referred to in paragraph (1)(a) or (b) is concluded.

Survey

188 (1) An operator must ensure that a survey, certified by a person licensed under the Canada Lands Surveyors Act, is conducted to confirm the location of any well and production installation.

Canada Lands Survey Records

(2) The operator must ensure that a copy of the survey plan must be filed with the Canada Lands Survey Records.

Survey plan

189 An operator must ensure that a copy of the survey plan filed with the Canada Lands Survey Records under subsection 188(2) is submitted to the Board.

Critical information

190 (1) In addition to the records required under section 177, an operator must ensure that records are kept of information and documents concerning:

Record retention periods

(2) The periods for which the operator must retain the records referred to in subsection (1) are the following:

Boilers and pressure systems

(3) The records referred to in subparagraphs (1)(h)(ii) and (iii) must be filled out and signed by the authorized inspector who conducted the inspection.

Daily production record

191 (1) An operator must ensure that a daily production record is kept until the field in which the pool or well is located is abandoned and, at that time, must offer to submit the record to the Board before destroying it.

Contents

(2) The daily production record must contain the records on the calibration of meters and other instruments referred to in paragraph 190(1)(d) and any other information relating to the production of petroleum and other fluids in respect of a pool or well, including

Formation flow test report

192 An operator must ensure that

Pilot scheme report

193 (1) An operator must ensure that interim evaluations of a pilot scheme referred to in section 81 are reported at intervals agreed to in writing by the Board.

Completion of pilot scheme

(2) On the completion of the pilot scheme, the operator must ensure that a report is submitted to the Board that sets out

Daily reports

194 An operator must ensure that the following items are submitted to the Board on a daily basis:

Monthly production report

195 An operator must ensure that a report summarizing the production data collected during a given month is submitted to the Board not later than the 15th day of the subsequent month.

Well reports and other information

196 (1) An operator must ensure that

Content of report

(2) The report required under paragraph (1)(a) must describe the manner in which the well has been abandoned, suspended, completed or recompleted and must include a schematic of the well illustrating the nature and location of the plugs used to abandon or suspend the well or the equipment used to complete or recomplete the well.

Required information

(3) The reports required under paragraphs (1)(b) to (d) must contain a record of all operational, engineering, petrophysical, geophysical and geological information that is relevant to the well operation, including any problems encountered during the well operation and the results of any formation leak-off test or formation integrity test conducted under section 70.

Impact description

(4) The report required under paragraph (1)(b) must describe any impact of the workover or intervention on the performance of the well, including any effect on productivity, injectivity and the recovery of petroleum.

Environmental report — drilling

197 An operator must ensure, in the case of a drilling installation for an exploratory well or a delineation well, an environmental report that relates to the well and that includes the following documents and information is submitted to the Board within 90 days after the day referred to in subparagraph 196(1)(a)(i), (ii) or (iii), as the case may be,

Annual environmental report — production and pipeline

198 An operator must ensure that, in the case of a production project or pipeline project, an environmental report that relates to a given calendar year and that includes the following documents and information is submitted to the Board not later than March 31 of the subsequent year:

Annual production report

199 An operator must ensure that, not later than March 31st of each year, an annual production report for a pool, field or zone is submitted to the Board that provides information on how the operator manages and intends to manage the resource without waste, including

Gas venting records

200 An operator must ensure that a record is kept of each gas venting under paragraph 82(b) that includes the following information:

Compressor records

201 An operator must ensure that a record containing the following documents and information is kept of the compressors referred to in subsection 83(2):

Fugitive emission records

202 An operator must ensure that a record is kept of the detection and repair of any fugitive emissions from an installation and that the record contains the following information in relation to each emission:

Record retention period

203 An operator must ensure that the records referred to in sections 200 to 202 are retained for five years after the day on which the record is created.

Diving Projects or Construction Activities

Weekly status reports

204 (1) An operator must ensure that weekly reports are submitted to the Board on the status of any diving project or construction activities.

Content of reports

(2) The weekly status reports must include the following documents and information:

PART 11
Repeals and Coming into Force

Repeals

205 The following Regulations are repealed:

Coming into Force

Six months after publication

206 These Regulations come into force on the day that, in the sixth month after the month in which they are published in the Canada Gazette, Part II, has the same calendar number as the day on which they are published or, if that sixth month has no day with that number, the last day of that sixth month.

SCHEDULE 1

(Clauses 27(1)(b)(ii)(A) and (B) and (iii)(B))

Certificate of Fitness

PART 1
Provisions of these Regulations

PART 2
Provisions of the Canada-Nova Scotia Offshore Area Occupational Health and Safety Regulations

SCHEDULE 2

(Subparagraph 30(3)(b)(iii))

Verification of Certificate of Fitness Requirements